Lennox Hearth Products LMDV-33 Series Скачать руководство пользователя страница 10

10

note: diaGraMs & iLLustrations are not to scaLe.

note: diaGraMs & iLLustrations are not to scaLe.

Burner adJustMents 

(QuaLiFied tecHnicians onLY)

Flame appearance and sooting

Proper flame appearance is a flame which is 

blue at the base and becomes yellowish-orange 

in the body of the flame.  When the appliance 

is first lit, the entire flame may be blue and will 

gradually turn yellowish-orange during the first 

15  minutes of operation. If after a short period 

the flame stays lowered blue, or if the flame is 

orange with evidence of sooting (black tip), the 

air shutter opening may need to be adjusted.

If the air shutter openings closed too far, sooting 

may develop. Sooting is indicated by black puffs 

developing at the tips of very long orange flames.  

Sooting results in black deposits forming on the 

logs, appliance inside surfaces and on exterior 

surfaces adjacent to the vent termination.  Soot-

ing is caused by incomplete combustion in the 

flames and lack of combustion air entering the 

air shutter opening. To achieve a warm yellow-

ish-orange flame with an orange body that does 

not soot, the shutter opening must be adjusted 

between these two extremes.  

air shutter adjustment Guidelines

•  If there is smoke or soot present, first check 

the log set positioning to ensure that the 

flames are not impinging on any of the logs.  

If the log set is properly positioned and a 

sooting  condition  still  exists,  then  the  air 

shutter opening should be increased.

•  The more offsets in the vent system, the larger 

the air shutter opening will need to be.

•  An appliance operated with the air shutter 

opened too far, may have flames that appear 

blue and transparent.  These weak, blue and 

transparent flames are termed anemic. 

•  Propane models may exhibit flames which 

candle or appear stringy. If this is present 

and persists, adjust the air shutter to a more 

open position, then operate the appliance for 

a few more minutes to ensure that the flame 

normalizes and the flames do not appear 

sooty. 

The following chart is provided to aid you in 

achieving  the  correct  air  shutter  adjustment 

for your installation.

air shutter adjustment Guidelines

:

amount of 

primary air

Flame 

color

air shutter 

adjustment

if air shutter is 

closed too far

Flame will 

be orange

air shutter 

gap should be 

increased

if air shutter is 

open too far

Flame will 

be blue

air shutter 

gap should be 

decreased

Figure 10 

Burner Flame appearance Model LMdV-3328 & LMdV-3530

Figure 11 

Burner Flame appearance Model LMdV-4035

     

WarninG

air  shutter  adjustment  should 

only be performed by a qualified 

professional service technician.

     WarninG

ensure front glass panel is in place 

and sealed during adjustment.

     

caution

the air shutter door and nearby 

appliance surfaces are hot.  exer-

cise caution to avoid injury while 

adjusting flame appearance.

Burner air shutter adjustment procedure

1

. Locate adjustment rod and adjust air shutter 

to the standard setting as shown in Figure 

12 (adjustment rod is located in the lower 

control compartment). Note: Rotating the 

adjustment rod clockwise decreases air and 

counterclockwise increases air.

 

2.

 Light appliance (follow lighting procedure on 

lighting label in control compartment or see 

homeowners manual).

3. 

Allow the burner to operate for at least 15 min-

utes while observing the flame continuously 

to ensure that the proper flame appearance 

has been achieved (see Figure 10 or 11

).

  If 

the following conditions are present, adjust 

accordingly.  

•  If flame appears weak or sooty, adjust 

the air shutter, incrementally, to a more 

open  position  until  the  proper  flame 

appearance is achieved.

•  If flame stays lowered blue, adjust the 

air  shutter,  incrementally,  to  a  more 

closed position until the proper flame 

appearance is achieved.

4.

 Leave the control knob (off/pilot/on) in the 

ON position and the burner OFF/ON switch 

OFF (& remote switches, if applicable). 

5. 

 When  satisfied  that  the  burner  flame  ap-

pearance is normal, close the lower control 

compartment door.

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Страница 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Страница 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Отзывы: