Lennox Hearth Products LMDV-33 Series Скачать руководство пользователя страница 13

13

note: diaGraMs & iLLustrations are not to scaLe.

accessorY coMponents

remote control Kit, standard

cat. no.

Model no.

description

H0249

rcL

remote control system  

(standard)

(ref. Form # 750,127M)

remote control Kit, deluxe

cat. no.

Model no.

description

H0251

rcL-stat

remote  control  system 

(deluxe)

(ref. Form # 750,129M)

(ref. Form # 750,037M)

digital

 

Wall thermostat

The wall thermostat kit provides temperature control 

for optimum comfort.

Wall thermostat, Millivolt

cat. no.

Model no.

description

H4635

dWtK

Wall thermostat Kit, 

White

product reference information

Cat. 

No.

Model

Ship. 

Weight

Ship.

 Volumn

H3313  LMdVt-3328cnM

95 lb.

13.08 cu. ft.

H3314 LMdVt-3328cpM

95 lb.

13.08 cu. ft.

H3315 LMdVr-3328cnM

95 lb.

13.08 cu. ft.

H3316 LMdVr-3328cpM

95 lb.

13.08 cu. ft.

H3317  LMdVt-3328cne

95 lb.

13.08 cu. ft.

H3318 LMdVr-3328cne

95 lb.

13.08 cu. ft.

H3319 LMdV-3530cnM

113 lb.

15.75 cu. ft.

H3320 LMdV-3530cpM

113 lb.

15.75 cu. ft.

H3321 LMdV-3530cne

113 lb.

15.75 cu. ft.

H3322  LMdV-4035cnM

147 lb.

20.18 cu. ft.

H3323 LMdV-4035cpM

147 lb.

20.18 cu. ft.

H3324 LMdV-4035cne

147 lb.

20.18 cu. ft.

rocker switch Kit

cat. no.

Model no.

description

80L41

Frs

rocker switch Kit

Arch Door Kit - Polished Brass

cat. no. 

Model

Fireplace Model

98L05

adK33cpB

LMdVt-3328, 

LMdVr-3328

26M43

adK35cMpB

LMdV-3530

81L35

adK40cpB

LMdV-4035

Arch Door Kit - Brushed Stainless Steel

cat. no. 

Model

Fireplace Model

98L62

adK33cBs

LMdVt-3328, 

LMdVr-3328

26M44

adK35cMBs

LMdV-3530

98L69

adK40cBs

LMdV-4035

arch door Kits

The arch door kits are easy to install and do not re-

quire hardware to attach them to the standard door 

frame. The decorative arch kits can not be used in 

conjunction with the screen panel kit.

(ref. Form # 750,021M)

unit-Mountable rocker switch

This  rocker  switch  kit  can  be  installed  directly  in 

the gas valve mounting bracket (millivolt gas valve 

equipped fireplaces) to provide On/Off operation in 

lieu of a wall switch.

standard remote control system 

The Model RCL (Standard) Remote Control System, 

features a simplistic OFF/ON control function for the 

fireplace.  This model includes a hand-held transmitter, 

a remote receiver with wall-mount cover plate and 

all hardware required to install the unit.  The remote 

receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are 

activated  by  pressing  either  button  on  the  face  of 

the transmitter.  When a button on the transmitter 

is pressed, a signal light illuminates briefly to verify 

that a signal has been sent.
The Model RCL is designed to operate with all mil-

livolt ignition systems, as well as electronic ignition 

systems.    It  may  be  installed  with  use  for  either 

natural  gas  or  propane  gas  appliances.    The  RCL 

offers ease of installation and allows you to execute 

on-off commands to the fireplace effortlessly with 

one simple  motion.
The Model RCL comes complete with detailed operat-

ing instructions.

deluxe remote control system 

The Model RCL-T (Deluxe) Remote Control System  

has all of the features of the standard system along 

with an added easy to read LCD screen which presents 

access  to  many  enhancements,  including;  battery 

power  level  indicator,  timer,  mode  of  operation, 

thermostatic display including room temperature in 

either metric of English units, flame indicator and 

clock.  Fully programmable, the Model RCL-T allows 

for virtual command over nearly all operational and 

temperature variables, using the hand held remote 

control transmitter.

The Model RCL-T (Deluxe) remote control system 

is  installed  in  the  same  manner  as  the  standard 

system, may be operated with electronic and mil-

livolt systems with either natural gas or propane gas.  

The RCL-T comes complete with detailed operating 

instructions.

Содержание LMDV-33 Series

Страница 1: ...OWED EXACTLY A FIRE OR EXPLO SIONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will...

Страница 2: ...LMDV 4035CNM LMDV 4035CPM 28 000 Table 3 TABLE OF CONTENTS Introduction Page 2 General Information Page 2 Gas Controls Access Page 3 Operation Care of Your Appliance Page 3 Variable Flame Adjustment...

Страница 3: ...latest edition Gas Pressure Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt models Fuel Low High Natural Gas Lo 2 2 WC 55 kPa Hi 3 5 WC 87 kPa Pr...

Страница 4: ...and off with the wall switch or remote control If your electronic appliance is not equipped with a wall switch or remote control the main burner must be turned off and on with the gas control switch T...

Страница 5: ...se improper and dangerous opera tion Verify proper operation after servicing Inspect and clean all wire connections Ensure that there is no melting or damage Inspection should include Terminals at the...

Страница 6: ...EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while the front glass enclosure panel or any of the panels is removed the fla...

Страница 7: ...8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested fo...

Страница 8: ...log E fits over pin on log A A V Shapeareaoflog E should aligntosidesofburnerports Log C fitsinto indentinLog A A SlotonbottomofLog C fitsoverbracket SlotonbottomofLog D fitsoverbracket Log D fits in...

Страница 9: ...notches onlog bottom rest on locating brackets Notch on log bottom fits over bracket Notch on log bottom fits over bracket SlotonbottomofLog D fitsoverbracket LOG SET Catalog Number H3365 Item Descrip...

Страница 10: ...for a few more minutesto ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your install...

Страница 11: ...ot generator thermopile and the top 1 8 minimum tip of the quick drop out thermocouple should be engulfed in the pilot flame The flame should project 1 25 mm beyond the hood at all three ports See Fig...

Страница 12: ...blower into J Box receptacle for FBK 100 or FBK 200 application See View A for J Box wiring Optional Blower OFF ON Switch Integral with Gas Valve Honeywell Electronic Gas Valve 120 VAC Primary Second...

Страница 13: ...can be installed directly in the gas valve mounting bracket millivolt gas valve equipped fireplaces to provide On Off operation in lieu of a wall switch Standard Remote Control System The Model RCL S...

Страница 14: ...0C 40 Sq Doors Charcoal LMDV 4035 H0951 SD40TI 40 Sq Doors Textured Iron H0952 SD40SP 40 Sq Doors Satin Pewter H0953 SD40AB 40 Sq Doors Antique Brass Style View Doors Square Pane Design Kits H0962 SPD...

Страница 15: ...speed 80L85 FBK 200 Blower Variable Speed w wall mounted switch 80L86 FBK 250 Blower Variable Speed w unit mounted switch 94L89 FBK 100 36 Blower Standard 36Pack 94L90 FBK 200 36 Blower Kit Variable...

Страница 16: ...e kits can be retrofitted to previously installed appliances ref Form 504 142M Eyebrow Hood Kits Polished Brass Brushed Stainless Models Where Used Cat Model Cat Model 98L10 EB33PB 98L11 EB33BS LMDVT...

Страница 17: ...Crescent Style lower grille shown ref Form 750 202M Note Door Trim Kits are for 1 side only If set is desired order 2 kits Decorative Grille Kits These decorative grilles are offered in two attractive...

Страница 18: ...echnician Force or attempted repair may result in a fire or an explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the app...

Страница 19: ...rique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le...

Страница 20: ...mediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Lighting Instructions Electronic 1 F...

Страница 21: ...ent pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteu...

Страница 22: ...or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform...

Страница 23: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 24: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 26: ...Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT H1657 1 88J53 1 13 Piezo Igniter 10K86 1 10K86 1 14 Pilot Assembly 69L17 1 69...

Страница 27: ...O SCALE NOTE THIS PAGE INTENTIONALLY LEFT BLANK NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts PA I N T 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20...

Страница 28: ...875 028M REV E 02 2008 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products...

Отзывы: