2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Offset Venting

Vertical Venting

Figure 1

TABLE OF CONTENTS

Packaging ........................................ page

2

Introduction ..................................... page

2

General Information ......................... page

2

Massachusetts and New York

  Requirements ................................ page

2

Location .......................................... page

4

Appliance  and Vent Clearances ....... page

4

Vent Termination Clearances ........... page

4

Typical Installation Sequence .......... page

4

Detailed Installation Steps ............... page

5

Step 1. Framing ............................. page

5

Step 2. Routing Gas Line ............... page

5

Step 3. Install the Venting System . page

5

Fireplace Specifications ................... page

6

Step 4. Field Wiring ....................... page 10

Step 5. Connecting Gas Line .......... page 11

Step 6. Outside Air Kit Installation . page 12

Step 7. Installing Logs ................... page 13

Step 8. Checking Unit Operation ..... page 13

Step 9. Installing Glass Enclosure

    Panels .......................................... page 13

Step 10. Burner Adjustment ............ page 14

Step 11. Spillage Test and Safety

    Limit Switch Operation ................ page 14

Step 12. Hood Installation ............... page 15

Finishing Requirements ................... page 15

Cold Climate Insulation .................... page 15

Gas Conversion Kits .................. page 16

TYPICAL INSTALLATION

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

Note:

 Installation and repair should be per-

formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.

This installation manual will help you achieve a
safe, efficient and dependable installation for
your appliance and vent system.

Please read and understand these

instructions before beginning your

installation.

GENERAL INFORMATION

PACKAGING

The  assembled vented gas fireplace is pack-
aged with:

1 - one log set located within the firebox.
2 - one plastic bag containing the literature

package, which consists of the homeowner's
manual, installation instructions, log place-
ment guide and warranty, 8 (EBVST), 4
(EBVPF, EBVCL and EBVCR) nailing flanges;
plastic bag is located on top of the fireplace.

3 - two hoods (EBVST, EBVCR, EBVCL), or

three hoods (EBVPF) taped to the top of the
fireplace.

4 - one plastic bag of glowing embers, one

plastic bag of decorative volcanic stone and
one bag of vermiculate is located in the
bottom compartment.

INTRODUCTION

These vented gas fireplaces are designed for
residential applications. They must be installed
with approved type-B, 6 in. double wall vent
pipe systems routed to the outside atmosphere.

The millivolt appliances are designed to operate
on either natural or propane gas. A millivolt gas
control valve with piezo ignition system provides
safe, efficient operation. If any optional accesso-
ries which require electrical power are being
installed, the electrical power must be provided
at the time of appliance installation.

Electronic appliances are designed to operate
on natural or propane gas. An electronic inter-
mittent pilot ignition system provides safe,
efficient operation. External electrical power is
required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-07A-5) to
ANSI Z21.50 - 2003 (in Canada, CSA 2.22 -
2003), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplaces.

These appliances may be used for bedroom
installations in the United States and are
listed accordingly.  These units may not be
installed in bedrooms in Canada.

Installation must conform to local codes. In the
absence of local codes, installation must com-
ply with the current National Fuel Gas Code,
ANSI Z223.1. (In Canada, the current CAN-1
B149 installation code.)  Electrical wiring must
comply with the National Electrical Code ANSI/
NFPA 70 - (latest edition).  (In Canada, the
current CSA C22-1 Canadian Electrical Code.)

WARNING:  THESE FIREPLACES ARE
VENTED DECORATIVE GAS APPLIANCES.
DO NOT BURN WOOD OR OTHER MATE-
RIAL IN THESE APPLIANCES.

Massachusetts And New York City, NY
Requirements

These appliances are approved for installation
in the following USA locations listed in the
following:

Massachusetts:

Installation of these fireplaces are approved
for installation in the US state of Massachu-
setts if the following additional requirements
are met-
• Installation and repair must be done by a
plumber or gas fitter licensed in the Common-
wealth of Massachusetts.
• The flexible gas line connector used shall not
exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-
handle type valve.

New York City, NY:

Installation of these fireplaces are approved
for installation in New Your City in the US state
of New York,  if the following additional re-
quirements are met-
• An outside air kit (FOAK-4 or FOAK-4LD)
must be installed.

Содержание EBVCLNE

Страница 1: ...rvice dos incendies L installationetservicedoit treex cut parunqualifi installeur agencedeserviceoulefournisseurdegaz B VENT MULTI OPEN ELITE SERIES B VENTED GAS FIREPLACES P N 850 025M REV B 01 2007...

Страница 2: ...c stone and one bag of vermiculate is located in the bottom compartment INTRODUCTION These vented gas fireplaces are designed for residential applications They must be installed with approved type B 6...

Страница 3: ...re not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases unless a certified kit is...

Страница 4: ...Height from Roof to Lowest Discharge Opening In addition when the unit is installed in the middle of a room the side walls surrounding the unit must not extend beyond the front or rear edge of the un...

Страница 5: ...tronic Appliances Connect 120 Vac electrical power to the appliance receptacle Step 5 page 11 Make connection to gas supply Step 6 page 12 OutsideAirKitInstallation Step 7 page 13 Install the log set...

Страница 6: ...nits is contemplated it should be dis cussed with an architect and the local Build ing Department Do not place insulation materials within 1 in of the gas vent system FIREPLACE FRAMING SPECIFICATIONS...

Страница 7: ...hes millimeters 6 159 9 248 Optional Gas Line Location Center of gas line is 3 in 76 mm up from floor Gas Line Center of gas line is 3 in 76 mm up from floor Minimum Framing Stud size is 2 x 4 41 1054...

Страница 8: ...top 1 2 13 DETAIL OF FINISH WALL BRACKET 13 2 ELECTRICAL INLETS B A B 8 203 DIA FLUE COLLAR 6 175 4 116 4 116 OUTSIDE AIR SHUTTER EBVPF Peninsula 12 305 20 510 TOP VIEW 40 1019 FRAMING SPACERS Top an...

Страница 9: ...2 20 510 OUTSIDE AIR SHUTTER 4 116 B A A 6 152 DIA FLUE OUTLET B 8 203 DIA FLUE COLLAR 13 24 610 6 175 12 305 2 70 3 76 13 41 1041 37 940 24 610 12 305 FRONT VIEW LEFT SIDE VIEW TOP VIEW 4 102 40 101...

Страница 10: ...out Remove the modesty panel care fully so that none of the wires become loose or disconnected 5 Remove the outlet receptacle by remov ing the two securing screws See Figure 17 The left and right desi...

Страница 11: ...in a potential safety hazard The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the National Electrical Code ANSI NFPA 70 latest edition In Ca...

Страница 12: ...duct vertically DO NOT terminate the duct closer than 3 below the chimney top Outside combustion air ducting may be run upwards or vertically through framing and ceiling joists with the hood installe...

Страница 13: ...he pilot The pilot flame should engulf the flame rod as shown in Figure 23 Replace logs after pilot inspection To light the burner turn ON the modesty panel mounted ON OFF switch and rotate the gas va...

Страница 14: ...the operation of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on the back of the switch To access the blocked flue safety li...

Страница 15: ...th of the mantel See Figure 27 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the hood Figure 2...

Страница 16: ...L TE JUSQU L OP RATION DE L APPAREIL CONVERTI EST CH QUE SUIVANT LES CRIT RES TABLIS DANS LES INSTRUCTIONS DE PROPRI TAIRE PROVISIONN ES AVEC L QUIPEMENT WARNING THIS CONVERSION KIT SHALL BE INSTALLED...

Страница 17: ...and 10 0 inches water column 2 49 kPa for propane gas See Figure 33 and replace the pilot orifice as follows Remove the ignitor assembly retainer clip andcarefullyremovetheignitorassembly Exercise ex...

Страница 18: ...placeitwiththeoneprovidedinthe kit See the following table for orifice sizes for natural and propane models Figure 34 illustrates the orifice B InstalltheburnersasshowninFigure29 The primary air openi...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 20: ...0 025M REV B 01 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: