10

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Step 4. FIELD WIRING

Refer to Section A for millivolt appliances and
Section B for electronic appliances. The gas
valve is set in place and pre-wired at the
factory on both models.

A. Millivolt Wiring 

(See Figure 16 )

1

. Appliance-mounted ON/OFF burner control

switch (rocker switch) is factory installed in
the modesty panel. Optional wall-mounted
switch, thermostat, or one of the optional
remote control kits may also be used.

2

. If wall-mounted ON/OFF control or thermo-

stat is selected, mount it in a convenient
location on a wall near the fireplace.

3

. Wire the control switch within the millivolt

control circuit using the 15 feet of 2 con-
ductor wire supplied with the unit.

Note:

 The supplied 15 feet of 2 conductor

wire has one end of each conductor con-
nected to the gas valve circuit and the other
end of each conductor  placed loose inside
the lower compartment of the unit.

Caution:  do not connect the optional wall

switch to a 120V power supply.

4.

If an optional control switch is installed,

turn the appliance-mounted ON/OFF burner
control switch to the OFF position.

Figure 16

3.

Remove the bottom control compartment

access panel by compressing the spring-
loaded hinge pin on the left side until it
disengages from the left cabinet panel
hole. Pull the panel away from the fire-
place. 

See Figure 20 on page 12.

4.

Remove the modesty panel by pulling the

bottom edge of the modesty panel out of
the locking slots of the cabinet bottom.
Then tilt the top edge at a 45

°

 angel and

lift out. Remove the modesty panel care-
fully, so that none of the wires become
loose or disconnected.

5

. Remove the outlet receptacle  by remov-

ing the two securing screws. See 

Figure

17.

 

(The left and right designations used

here are reversed in EBVCR applications.)

6

. Install a field-provided strain relief in the

cabinet knockout opening for the protec-
tion of the power supply wires.

7

. Connect the power supply wires to the

receptacle as shown in 

Figure 18 on

page 11.

8

.

Connect the ground supply wire and the

green wire attached to the outlet
receptacle's green ground screw.

9

. Appliance-mounted ON/OFF burner con-

trol switch (rocker switch) is factory in-
stalled in the modesty panel. Optional
wall-mounted  switch, thermostat, or one
of the optional remote control kits may
also be used.

Thermopile

TH

TP

TH

TP

White

White

Black

Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

*OPTIONAL WALL-MOUNTED ON/OFF

SWITCH OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

*Turn the appliance-mounted ON/OFF burner control

switch to the OFF position if an optional

control switch is installed.

Factory Wired

Field Wired

Schematic Representation Only

APPLIANCE-MOUNTED ON/OFF SWITCH

LIMIT SWITCH

B. Electronic Wiring
(also see Figure 18 on page 11 )

Note:

 The electronic appliance must be con-

nected to the main power supply.

1

. Route a 3-wire 120Vac 60Hz 1ph power

supply to the appliance junction box.

2.

Open the control compartment access

panel, by actuating the spring-loaded
magnetic catches securing the panel,
gently depressing the outer top corners
of the panel until the catches "pop" the
panel free and allowing it to swing out
and down to open.

Содержание EBVCLNE

Страница 1: ...rvice dos incendies L installationetservicedoit treex cut parunqualifi installeur agencedeserviceoulefournisseurdegaz B VENT MULTI OPEN ELITE SERIES B VENTED GAS FIREPLACES P N 850 025M REV B 01 2007...

Страница 2: ...c stone and one bag of vermiculate is located in the bottom compartment INTRODUCTION These vented gas fireplaces are designed for residential applications They must be installed with approved type B 6...

Страница 3: ...re not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases unless a certified kit is...

Страница 4: ...Height from Roof to Lowest Discharge Opening In addition when the unit is installed in the middle of a room the side walls surrounding the unit must not extend beyond the front or rear edge of the un...

Страница 5: ...tronic Appliances Connect 120 Vac electrical power to the appliance receptacle Step 5 page 11 Make connection to gas supply Step 6 page 12 OutsideAirKitInstallation Step 7 page 13 Install the log set...

Страница 6: ...nits is contemplated it should be dis cussed with an architect and the local Build ing Department Do not place insulation materials within 1 in of the gas vent system FIREPLACE FRAMING SPECIFICATIONS...

Страница 7: ...hes millimeters 6 159 9 248 Optional Gas Line Location Center of gas line is 3 in 76 mm up from floor Gas Line Center of gas line is 3 in 76 mm up from floor Minimum Framing Stud size is 2 x 4 41 1054...

Страница 8: ...top 1 2 13 DETAIL OF FINISH WALL BRACKET 13 2 ELECTRICAL INLETS B A B 8 203 DIA FLUE COLLAR 6 175 4 116 4 116 OUTSIDE AIR SHUTTER EBVPF Peninsula 12 305 20 510 TOP VIEW 40 1019 FRAMING SPACERS Top an...

Страница 9: ...2 20 510 OUTSIDE AIR SHUTTER 4 116 B A A 6 152 DIA FLUE OUTLET B 8 203 DIA FLUE COLLAR 13 24 610 6 175 12 305 2 70 3 76 13 41 1041 37 940 24 610 12 305 FRONT VIEW LEFT SIDE VIEW TOP VIEW 4 102 40 101...

Страница 10: ...out Remove the modesty panel care fully so that none of the wires become loose or disconnected 5 Remove the outlet receptacle by remov ing the two securing screws See Figure 17 The left and right desi...

Страница 11: ...in a potential safety hazard The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the National Electrical Code ANSI NFPA 70 latest edition In Ca...

Страница 12: ...duct vertically DO NOT terminate the duct closer than 3 below the chimney top Outside combustion air ducting may be run upwards or vertically through framing and ceiling joists with the hood installe...

Страница 13: ...he pilot The pilot flame should engulf the flame rod as shown in Figure 23 Replace logs after pilot inspection To light the burner turn ON the modesty panel mounted ON OFF switch and rotate the gas va...

Страница 14: ...the operation of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on the back of the switch To access the blocked flue safety li...

Страница 15: ...th of the mantel See Figure 27 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the hood Figure 2...

Страница 16: ...L TE JUSQU L OP RATION DE L APPAREIL CONVERTI EST CH QUE SUIVANT LES CRIT RES TABLIS DANS LES INSTRUCTIONS DE PROPRI TAIRE PROVISIONN ES AVEC L QUIPEMENT WARNING THIS CONVERSION KIT SHALL BE INSTALLED...

Страница 17: ...and 10 0 inches water column 2 49 kPa for propane gas See Figure 33 and replace the pilot orifice as follows Remove the ignitor assembly retainer clip andcarefullyremovetheignitorassembly Exercise ex...

Страница 18: ...placeitwiththeoneprovidedinthe kit See the following table for orifice sizes for natural and propane models Figure 34 illustrates the orifice B InstalltheburnersasshowninFigure29 The primary air openi...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 20: ...0 025M REV B 01 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: