Lennox Hearth Products EBVCLNE Скачать руководство пользователя страница 13

13

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 24 -
Installing the Glass Enclosure Panel

Glass
Enclosure
Panel
Latch

Lower Compartment Door and Hinge

Front Glass
Enclosure Panel

Firebox
Floor

Bottom Vee-flanges

(Glass Enclosure

Panel Frame)

Top Flange
(Glass Enclosure
Panel Frame)

Modesty Panel

EBVST SHOWN

WARNING: HANDLE THE GLASS WITH
EXTREME CARE!  TEMPERED GLASS IS
SUSCEPTIBLE TO DAMAGE (SCRATCHES,
FOR EXAMPLE) – HANDLE GLASS DOOR
(GLASS ENCLOSURE PANEL) GENTLY
WHILE REINSTALLING IT.

WARNING: NEVER OPERATE THE APPLI-
ANCE WITHOUT THE FRONT GLASS EN-
CLOSURE PANEL IN PLACE AND SECURE.

Figure 22

Figure 23

The top 

³⁄₈

" (10 mm) at the pilot generator

(thermopile) and the top 

¹⁄₈

" min (tip) of the

quick drop out thermocouple should be en-
gulfed in the pilot flame. The flame should
project 1" (25 mm) beyond the hood at all three
ports

 (Figure 22)

.

Millivolt Appliance Checkout

The pilot flame should be steady and, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.

Step 7. INSTALLING LOGS, VERMICULITE,
DECORATIVE VOLCANIC STONE AND
GLOWING EMBERS

The log set is located within the firebox. One
plastic bag of glowing embers, one plastic bag
of decorative volcanic stone and one bag of
vermiculate, is located in the bottom compart-
ment. Refer to the 

Log Placement Guide

 for

detailed placement instructions for the log set
and glowing embers.  See the 

Homeowners

Manual

 for placement instructions of vermicu-

late, decorative volcanic stone and rockwool.

Step 8. CHECKING APPLIANCE OPERATION

With gas line installed run initial system check-
out before closing up the front of the unit.
Follow the pilot lighting instructions provided
in the Homeowner's Care and Operation In-
structions. For piezo ignitor location see

 

Figure

20 on page 12 

(millivolt appliances only).

Note: Lighting instructions may also be found
on the pull out lighting instruction labels
attached to the gas control valve

.

Step 9. INSTALLING GLASS ENCLOSURE
PANELS

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the modesty
panel mounted ON/OFF switch and turn the gas
control switch to the “ON” position.  Ensure the
ignitor lights the pilot. The pilot flame should
engulf the flame rod as shown in 

Figure 23

.

Replace logs after pilot inspection.

To light the burner; turn “ON” the modesty
panel mounted ON/OFF switch  and rotate the
gas valve control knob counterclockwise to
the “ON” position.

When first lighting the appliance, it will take
a few minutes for the line to purge itself of
air. Once purging is complete, the pilot and
burner will light and operate as indicated in
the instruction manual. Subsequent lightings
of the appliance will not require such purg-
ing. Inspect the pilot flame (remove logs, if
necessary, handling carefully).

1.

  Visually inspect the gasket on the backside

of the panels. The gasket surface must be
clean, free of irregularities and seated firmly.

2. 

Position the glass enclosure panel in front

of the firebox opening at a 45 degree angle and
engage the top flange over the lip at the top of
the firebox opening. 

See Figure 24.

3. 

 Swing the glass enclosure panel down and

back.  Ensure the gasket seats evenly as the
panel draws shut.  Engage the Vee-flanges at
the bottom of the panel with the latches; then
close the latches to secure the panel.

4.

 After installing the front glass enclosure

panel, reinstall the bottom control compart-
ment access panel by inserting the right side
locating pin into the right side cabinet panel
and then the left side spring-loaded pin into
the left side cabinet panel.

Figure 21

Operate the actuator through several cycles
including the closed position.  Ensuring proper
operation and freedom of movement.  Return
the actuator arm to the closed position.

Outside Air Control Lever

 and Securing Screw Location

(EBVST, EBVPF and EBVCR Units Shown)

The outside air shutter should be fully open when
the fireplace is in use and completely closed
when the fireplace is not being used.  Closing it
when not in use will prevent outside cold air from
entering the dwelling.

To access the label, see the procedure on the
previous page described for accessing the gas
control valve.

MILLIVOLT

Thermocouple

Hood

Ignitor Rod

³⁄₈

" Min

(9 mm)

Thermopile

Pilot
Nozzels

ELECTRONIC

Proper Flame

Adjustment

Pilot
Nozzle

3/8 To 1/2 Inch

(9 mm to 13 mm)

Ground
Electrode

Flame Rod

Hot Surface

Igniter

Outside Air Control Lever with Stop Behind

Securing Screw

Outside Air Shutter in the
Closed Position

Control Compartment Access Panel

Содержание EBVCLNE

Страница 1: ...rvice dos incendies L installationetservicedoit treex cut parunqualifi installeur agencedeserviceoulefournisseurdegaz B VENT MULTI OPEN ELITE SERIES B VENTED GAS FIREPLACES P N 850 025M REV B 01 2007...

Страница 2: ...c stone and one bag of vermiculate is located in the bottom compartment INTRODUCTION These vented gas fireplaces are designed for residential applications They must be installed with approved type B 6...

Страница 3: ...re not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases unless a certified kit is...

Страница 4: ...Height from Roof to Lowest Discharge Opening In addition when the unit is installed in the middle of a room the side walls surrounding the unit must not extend beyond the front or rear edge of the un...

Страница 5: ...tronic Appliances Connect 120 Vac electrical power to the appliance receptacle Step 5 page 11 Make connection to gas supply Step 6 page 12 OutsideAirKitInstallation Step 7 page 13 Install the log set...

Страница 6: ...nits is contemplated it should be dis cussed with an architect and the local Build ing Department Do not place insulation materials within 1 in of the gas vent system FIREPLACE FRAMING SPECIFICATIONS...

Страница 7: ...hes millimeters 6 159 9 248 Optional Gas Line Location Center of gas line is 3 in 76 mm up from floor Gas Line Center of gas line is 3 in 76 mm up from floor Minimum Framing Stud size is 2 x 4 41 1054...

Страница 8: ...top 1 2 13 DETAIL OF FINISH WALL BRACKET 13 2 ELECTRICAL INLETS B A B 8 203 DIA FLUE COLLAR 6 175 4 116 4 116 OUTSIDE AIR SHUTTER EBVPF Peninsula 12 305 20 510 TOP VIEW 40 1019 FRAMING SPACERS Top an...

Страница 9: ...2 20 510 OUTSIDE AIR SHUTTER 4 116 B A A 6 152 DIA FLUE OUTLET B 8 203 DIA FLUE COLLAR 13 24 610 6 175 12 305 2 70 3 76 13 41 1041 37 940 24 610 12 305 FRONT VIEW LEFT SIDE VIEW TOP VIEW 4 102 40 101...

Страница 10: ...out Remove the modesty panel care fully so that none of the wires become loose or disconnected 5 Remove the outlet receptacle by remov ing the two securing screws See Figure 17 The left and right desi...

Страница 11: ...in a potential safety hazard The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the National Electrical Code ANSI NFPA 70 latest edition In Ca...

Страница 12: ...duct vertically DO NOT terminate the duct closer than 3 below the chimney top Outside combustion air ducting may be run upwards or vertically through framing and ceiling joists with the hood installe...

Страница 13: ...he pilot The pilot flame should engulf the flame rod as shown in Figure 23 Replace logs after pilot inspection To light the burner turn ON the modesty panel mounted ON OFF switch and rotate the gas va...

Страница 14: ...the operation of this safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on the back of the switch To access the blocked flue safety li...

Страница 15: ...th of the mantel See Figure 27 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however do not allow anything to hang below the hood Figure 2...

Страница 16: ...L TE JUSQU L OP RATION DE L APPAREIL CONVERTI EST CH QUE SUIVANT LES CRIT RES TABLIS DANS LES INSTRUCTIONS DE PROPRI TAIRE PROVISIONN ES AVEC L QUIPEMENT WARNING THIS CONVERSION KIT SHALL BE INSTALLED...

Страница 17: ...and 10 0 inches water column 2 49 kPa for propane gas See Figure 33 and replace the pilot orifice as follows Remove the ignitor assembly retainer clip andcarefullyremovetheignitorassembly Exercise ex...

Страница 18: ...placeitwiththeoneprovidedinthe kit See the following table for orifice sizes for natural and propane models Figure 34 illustrates the orifice B InstalltheburnersasshowninFigure29 The primary air openi...

Страница 19: ...19 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 20: ...0 025M REV B 01 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: