20
8. USEFUL NOTES
8.1 Tone-dialling command
If you want to use
to its full potential a tone-dialling telephone is necessary. Nowadays most of the
telephones in use are working on tone dialling, also called DTMF or in-band signalling. Older telephones are using pulse
dialling. In case there is no tone-dialling telephone available, the features shown in section 7.7.3 cannot be used
Note:
An acoustic coupler can be purchased in electronic shops.
8.2 User information
8.2.1 Signals (beeps)
A single beep tone is used as a confirmation
Three beep: Mains power loss AND battery low at the same time!
8.2.2 Announcement audible in loudspeaker of EasyAlarm®
Announcement
Message / Cause
„Individual message“
First message in case of an alarm
Abort
Disconnection caused from the change of the position of the
selection switch
Alarm due to presence
verification
Triggered emergency call due to loss of presence
Alarm acknowledged
Disconnection
Battery error
Battery is low => battery test after power on
Calling number
n
Calling number
n (=1..9)
Calling number error
First calling number in the calling number sequence is not programmed
Calling number sequence
Calling number sequence
Emergency call activated
Emergency call, initiated by emergency button
Emergency call deactivated,
alarm acknowledged
Emergency call confirmed
Error
Incorrect programming => the old value remains stored
Line check error
Telephone line check after power on was negative => dial tone missing
Output activated
The output is activated after power on.
PIN
Request to enter PIN-Codes by locked programme
Power failure
Mains power missing => Mains power is tested after switching on the unit
Presence verification activated
Motion sensor is set to presence verification
Programming deactivated: PIN
Request to enter PIN-Code to unlock programming
Supervision (I/II/III) <due to
noise/sensor
n>
activated
Announcement of the monitored alarm functions at current position of the
selection
switch
(I/II/III) triggered by pressing key
5
.
during the
inactive waiting period
(
section 7.3.1.1)
Supervision (I/II/III) activated
Announcement in active supervision mode at current position of the
selection switch
(I/II/III)
Supervision (I/II/III) deactivated
Announcement in active supervision mode at current position of the
selection switch
(I/II/III)
to modify press * , to stop press #
Recording of
individual message
Unacknowledged alarms:
n
Quantity of unacknowledged alarms
8.2.3 Announcements audible in the handset of called subscriber
as well as during
hands-free connection
in loudspeaker of
Announcement
Message / Cause
„Individual message”
First message in case of an alarm or reaction on DTMF 2 .
Abort
Phone connection
will be terminated
Alarm due to noise
Alarm triggered by noise activity (Note: according to
selection switch
position
I,II,III the alarm can be delayed)
Alarm due to presence
verification
Triggered emergency call due to loss of presence
Alarm due to programming
A test call was initiated due to remote programming (
section 10.8.2)
Alarm due to sensor
n
sensor
n
activated
sensor failure
Reason of alarm: alarm contact
n
.
sensor
n
is in alarm mode
disconnection of sensor during operation
Battery error
Battery is low => battery test before
phone connection
is established
Emergency call activated
Emergency call, initiated by emergency button
Emergency call due to sensor
Emergency call triggered due to loss of presence verification
Output <activated / deactivated>
c
onfirmation of < DTMF 6 / DTMF 4 > (
section 11.4)
PIN
Request to enter PIN-Code after dialling in (remote access)
PIN error, abort
Wrong PIN-code =>
Phone connection
terminated
Power failure
Mains power loss => Mains power is tested every time before
phone connection
is