7. OPERATION
7.1 Self check at power on
After power on the alarm unit checks battery, mains power and telephone-line conditions. If one of these tests fails an
appropriate message will be announced (battery error/power failure/line-check error).
Three beep: Mains power loss AND battery low at the same time!
Quickly handle the announce problem, otherwise the alarm functions are not guarantied.
7.1.1 Detection of wired sensor
detects the connected motion sensor automatically during the switching on procedure (factory setting). This
sensor is activated for presence verification
Important notes:
By disconnecting the motion detector during the operation mode, an alarm is triggered followed by the
announcement: ”alarm due to sensor 1, sensor failure!”
By connecting the motion detector after the start up procedure of the alarm unit, an alarm is triggered followed by
the announcement: “alarm due to sensor 1, sensor 1 activated!”
7.2 Arm / Disarm system
After power on
automatically arms the system. During operation
can be armed/disarmed
using the remote control or during any telephone connection using DTMF 7 and 9 .
Announce “supervision activated “ or “supervision deactivated”
7.3 Inactive waiting period
7.3.1 After power on or changing position of selection switch (exit delay)
remains inactive for 20 seconds (LED is on continuously), to leave time to quit your room/house without
triggering an alarm. An emergency call by pressing the emergency button is still possible.
Note:
The entry/exit period can be adjusted according to section 10.3.
If there are unacknowledged alarms, their quantity and the reason of the last alarm will be announced.
If presence verification is activated, following announcement is made: "Presence verification activated".
Key
Action
5
Announcement of the monitored functions
(
inactive waiting period
will be restarted)
7
Bypass
waiting period
and change to inactive supervision mode
Attention: by switching from activated to inactivated supervision mode, an announcement of the
supervision modes is made and the waiting period starts again.
9
Bypass
waiting period
and change to active supervision mode
Attention: by switching from inactivated to activated supervision mode, an announcement of the
supervision mode is made and the waiting period starts again.
others
Test-call
will be made to the first calling number
7.3.1.1
Announcement of the supervision functions
The supervision functions can be activated or deactivated individually on each position of the selection switch
deactivated
announcement: "Supervision I/II/III deactivated"
activated
announcement: "Supervision I/II/III”
followed by the supervision mode of the
activated
type of monitoring:
acoustical monitoring
announcement: "due to noise"
sensor-1 monitoring
announcement: "due to sensor 1”
sensor-2 monitoring
announcement: "due to sensor 2”
sensor-3 monitoring
announcement: "due to sensor 3” .. “activated”
7.3.2 ..after an successful alarm
remains inactive for two minutes (LED is on continuously) to avoid too many alarms due to sensor contacts.
An emergency call is still possible during this period.
Any key-press
results in a test call to the first calling number.