Repairs must only be carried out by authorized Leister service centers.
Leister service centers guarantee a professional and reliable repair service with original spare parts in accordance with circuit
diagrams and spare parts lists. You will find the address of your authorized service center on the last page.
You can find more information at www.leister.com.
15. Service and Repair
Leister Technologies AG and its authorized service centers offer welding courses and training sessions.
You can find more information at www.leister.com.
16. Training Course
• The guarantee or warranty rights granted for this device by the direct distribution partner/salesperson apply from the date of purchase.
• In the event of a guarantee or warranty claim (verification by invoice or delivery note), manufacturing or processing errors will
be rectified by the sales partner through replacement delivery or repair.
• Other guarantee or warranty claims are excluded within the framework of mandatory law.
• Damages resulting from natural wear, overload, or improper handling are excluded from the warranty.
• Heating elements shall be excluded from warranty obligations or guarantees.
• No guarantee or warranty claims exist for devices which have been converted or changed by the purchaser or for which
non-original Leister spare parts have been used.
17. Warranty
A
Within the limits
Green lamp
signal.
B
Outside the limits
Heating/cooling or standby phase
Red lamp
signal.
B
Outside the limits
During welding,
an alarm
is emitted
in addition
to the
red lamp.
+
14.1.4 Operating Hours Counter
The operating hours counter is active as soon as the monitoring unit is connected. The operating hours counter remains active
when the monitoring unit is switched off
.
Machine operating hours
Zählt die Betriebsstunden der Seamtek 900 AT. Dieser Wert kann nicht zurückgesetzt
werden.
Betriebsstunden Luftpumpe
Zählt die Betriebsstunden der Luftpumpe. Dieser Wert kann über das Symbol zu-
rückgesetzt werden.
Betriebsstunden Heizung
Zählt die Betriebsstunden des Heizelementes. Dieser Wert kann über das Symbol
zurückgesetzt werden.
Anzahl Aufheizzyklen
Misst die Anzahl der Aufheizzyklen des Heizelements. Die Anzahl Aufheizzyklen wird um
1 inkrementiert, sobald die Ist-Temperatur mindestens 200 °C / 392 °F beträgt und
mindestens 90 % der Solltemperatur erreicht hat. Fällt die Ist-Temperatur erneut unter
120 °C, kann bei obigen Bedingungen die Anzahl Aufheizzyklen erneut inkrementiert
werden. Die Anzahl Aufheizzyklen kann über das Symbol zurückgesetzt werden.