Connect a suitable compressed air cable to the
compressed air connection (19)
and connect
the cable to a source that supplies a minimum
of 8 bar. Set the
compressed air controller
to 6.5 bar.
The Seamtek is supplied with a quick coupling (19)
but not a hose connector. Use an in-house hose
connector with an external thread of R/Rc ¼".
Screw this connector into the internal thread of
the quick coupling (19). Connect the in-house
hose to the hose connector. Now connect the
hose to a compressed air source that supplies
a minimum of 6.5 bar (94 psi) and a maximum
of 10 bar (145 psi). Inspect the pressure at the
pressure gage within the pneumatic-system
cabinet (26). Adjust the pressure with the hand
wheel as necessary.
4.9 Connecting the Compressed-Air Supply
19
5.1 Type Plate and Identification
5. Your SEAMTEK 900 AT
The type designation and serial number are specified on the type plate on your device.
Transfer this information to your operating instructions; in the event of any inquiries
to our representatives or authorized Leister service center, please always refer to this
information.
Article no.:
Serial no.:
5.2 Scope of Delivery (standard model in transport box)
1 x Seamtek AT 900
2 x 25 mm steel rollers, mounted
1 x pedestal, mounted
1 x connection cable (without plug)
1 x quickarm, optionally mounted (optional accessory)
2 x key for switch cabinet
1 x sidearm, optionally mounted (optional accessory)
1 x operating manual
1 x tape delivery system, optionally mounted (optional accessory)
1 x wiring diagram
1 x 25 mm nozzle, mounted
Connection cable
International (230 V):
Function
USA (240 V):
Function
Wire colors
Connection cable
Machine
brown
L1 (230V AC)
L1 (120V AC)
light blue
N
L2 (120V AC)
yellow/green
PE
PE