18
_________________________________________________________________________________
6.2.4 230V - Connection and switches (Option)
1. 230V 50Hz, 16A connecting cable
2. Switch of residual current device. The switch must be in
”ON” position in order that any 230V device will work,
including the 230V outlets. With the TEST button one can
test the function of the residual current device, and also if
there is 230V current coming from the network. If the
residual current does not go off when pushing the TEST
button, it is either defect or then there is no current
coming from the network (the connecting cable must be
connected of course).
3. Battery charger. There are two indicators on the charger
which show the charge level of the battery: Yellow
indicator on = low charge; Yellow and green indicator on
= battery almost fully charged; Green indicator on =
battery fully charged / trickle charge
Picture 8. 230V use
6.2.5 Lower control panel (Option)
1. Selector switch, upper / lower controls
2. Ignition switch: Stop
– ON – Start
3. Power source: Diesel engine or electric motor
(option)
4. Glow indicator (diesel)
5. Platform overload indicator
6. Dead man button (option)
7. Emergency stop switch
8. Outrigger monitoring or Emergency stop & platform
load monitoring override switch
9. Lower boom lever
10. Upper boom lever
11. Slewing lever
12. Telescope lever
13. Upper boom lever
Picture 9. Lower controls
Use of lower controls:
1. The ignition switch at main electric box on the pedestal (picture 7)
must be turned to ”ON”
position.
2. Boom operations only work when the mode selector switch in platform (picture 5) is in
Boom selection.
3. Select with the selector key switch no. 1 either lower controls or upper controls at
platform. The machine can be operated either with lower or upper controls, but not with
both at the same time.
4. When lower controls are selected the engine/electric motor can be started and stopped
with the ignition switch no. 2 at lower controls.
5. When the engine/motor is running the booms can be operated
– except for platform tilting
– with the control levers of lower controls.
ATTENTION! The EMERGENCY STOP switch at lower controls works always,
regardless of the position of the selector switch of lower/upper controls.
1
2
3
9
2
3
6
1
7
8
10
13 12 11
B
A
4
5