LEGRAND TyneTec Advent XT2 ascom VoWiFi i62 Скачать руководство пользователя страница 8

Doc No. FM0855 issue 2 Page 8   

 

PIN No. 

Cat5e WIRE COLOUR 

 

 

White/Orange 

Orange 

White/Green 

Blue 

White/Blue 

Green 

White/Brown 

Brown 

 

4

5

8

7

3

6

2

1

        P10280  TYPE  "A"

CUT  BOTH  RESISTORS  OFF  PCB

4
5

8
7

3
6
2
1

            P10280  TYPE  "B"

NO  RESISTORS  BUT  DIFFERENT  PIN-OUT

7. SITE WIRING REQUIREMENTS 

 

ASCOM VoWiFi SYSTEM 

ABC

F

E

D

I

H

G

L

K

J

O

N

M

V

U

T

S

R

Q

P

Z

Y

X

W

ACT

USB

2.4G

5G

LAN A1

LAN A2

LAN A3

LAN A4

LAN B

asco

m

ACT

USB

2.4G

5G

LAN A1

LAN A2

LAN A3

LAN A4

LAN B

ACT

USB

2.4G

5G

LAN A1

LAN A2

LAN A3

LAN A4

LAN B

 

 

ETHERNET EXTENSION 

If the Mesh Root Access Point needs to be located in a remote location  
where the 2m 

UTP Patch lead provided isn’t long

 enough to reach the  

Matrix IP-PBX, then Cat5e cable and RJ45 wall sockets will be required. 

  

Wire between the wall sockets using Cat5e Ethernet U/UTP cable (Belden Type: 1583E.00B100) or 
equivalent (Tynetec P/No. YW1731). The total cable length must not exceed 

100 metres

. For distances 

greater than 100m an additional Ethernet switch or LAN extender will be required in series. 

 

 
 
 

 

 
 
 
 
 
 
 
 
 

RJ45 WALL SOCKET (REAR)

 

 

 

 

 
 
 
 
 

 
 

RJ45 Wall Socket:  
Tynetec Part No. P10280 

 

Surface Backbox:  
Tynetec Part No. O15090

 

 

2m UTP Patch Lead: 
Tynetec Part No. W00402

 

 

2m Patch Lead 

2m Patch Lead 

Cat5e Cable (Max 96m) 

 

Make all 8 connections

 

Matrix IP-PBX 

RJ45 Wall Socket 

RJ45 Wall Socket 

Mesh Root 

Access Point 

Ethernet Port 

LAN A1 

Mains Adapter 

 

Содержание TyneTec Advent XT2 ascom VoWiFi i62

Страница 1: ...s the right to modify the specification of its products If any variation to the details in this document are suspected please contact Tynetec s Technical Support Tynetec a business unit of Legrand Ele...

Страница 2: ...AP 903 Access Point 12 11 Mesh Access Point Installation 14 12 VoWiFi System Installation Overview 15 13 Laptop Setup for Draytek Devices 16 14 Check Upgrade Draytek Firmware 17 15 Mesh Root Setup 18...

Страница 3: ...i62 handsets have their WiFi settings and SIP credentials preconfigured as extensions 151 and 152 A maximum of 5 IP extensions 151 to 155 are possible The Matrix IP PBX allows the VoWiFi handsets to i...

Страница 4: ...is manual for details of cable type and cable length restrictions Mesh Access Points should be located at least 5 metres away from any other electronic equipment Failure to provide this separation may...

Страница 5: ...The EU Directive 2006 6 EC has been put in place to ensure the safe disposal and recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depo...

Страница 6: ...ediate obstruction as possible will help to maximise its range Even if the Access Point is placed in the optimum position it may not always achieve coverage in the most remote corners if this is the c...

Страница 7: ...nd user guides ASCOM DOCUMENTS You can request copies of the documents listed below from Tynetec s customer support Quick Reference Guide for Ascom i62 VoWiFi Handset User Manual for Ascom i62 VoWiFi...

Страница 8: ...ted in a remote location where the 2m UTP Patch lead provided isn t long enough to reach the Matrix IP PBX then Cat5e cable and RJ45 wall sockets will be required Wire between the wall sockets using C...

Страница 9: ...the adapter PRECONFIGURED HANDSETS The 2 ascom i62 VoWiFi handsets supplied with ZXT964 Matrix IP PBX bundle have been preconfigured as SIP extensions 151 and 152 i62 Wi Fi settings Wi Fi SSID ADVENT...

Страница 10: ...dden Admin menu Scroll to VoIP and press Select soft key Select Endpoint Number press Edit soft key and then edit this field which is the desired extension number on the Matrix IP PBX e g 153 and pres...

Страница 11: ...ort for up to 5 IP extensions VoWiFi handsets and 2 analogue extensions for standard SLT desk telephones IP PBX CONNECTIVITY IP PBX CONFIGURATION The Matrix NENX IP PBX is supplied with a standard Tyn...

Страница 12: ...via a PoE switch LAN A1 Port only Draytek Vigor AP 903 WLAN WPS BUTTON Not used in this application FACTORY RESET BUTTON This button is used to restore the default settings When the Access Point is o...

Страница 13: ...1 A4 On Ethernet LAN A1 is connected Off Ethernet LAN A1 is disconnected LAN A2 A4 Off Ethernet LAN A2 A4 is disconnected On Ethernet LAN A2 A4 is connected Blinking Data is being transmitted on the E...

Страница 14: ...ts WALL MOUNTING THE DRAYTEK VIGOR AP 903 1 Drill 2 holes in the wall using a 6 5mm drill bit The vertical distance between the holes should be 80mm assuming the wall plugs and screws provided are bei...

Страница 15: ...ne PSU module provided CO1 connect to the Advent XT2 DECT 1 output using the RJ11 BT lead provided CO2 connect to an external telephone line using the RJ11 BT lead provided SLT1 connect to the CLI des...

Страница 16: ...ocal Area Connection 2 Right click and select Properties of the LAN Network Port that will be used 3 Select the Internet Protocol Version 4 TCP IPv4 and select Properties as shown below 4 Enter the IP...

Страница 17: ...ce menu then select Firmware Upgrade as shown below The Current Firmware Version should be 1 3 3 or higher If an upgrade is required go to https www draytek co uk support downloads and select VigorAP...

Страница 18: ...art Wizard as shown below Operation Mode select Mesh Root from the Operation Mode list box then press Next Step I WiFi Setup change the WiFi Name to ADVENT and the Password to LEGRAND1 De select the E...

Страница 19: ...shown below In the LAN IP Network Configuration de select the Enable DHCP Client checkbox Enter the IP address 192 168 0 50 Mesh Root IP address Enter the Subnet Mask 255 255 255 0 Enter the Default...

Страница 20: ...ion Select Strictly Minimum RSSI 73dBm 42 then press OK I Go to the Wireless LAN 5GHz menu and repeat the same settings as the Wireless LAN 2 4GHz i e Select General Setup Ensure the Enable wireless L...

Страница 21: ...address 192 168 0 51 for Mesh Node 1 For Mesh Node 2 enter 192 168 0 52 through to Mesh Node 7 enter 192 168 0 57 Enter the same Subnet Mask 255 255 255 0 for all Mesh Nodes 1 7 Enter the same Default...

Страница 22: ...and select Mesh Setup as shown below Scroll down to the Add Mesh Node section and press the Search button Wait for the devices to appear in the Search List then select the check box next to each devi...

Страница 23: ...d Mesh Node it must be no less than 73dB For example 74dB or greater will be out of range and you need to move the Mesh Node closer to the Mesh Root If the dB level displayed is 66dB for example then...

Страница 24: ...t to the Mesh Root and view the Dashboard or use the Draytek Wireless App 2 Check the WiFi signal strength and route connections of all Mesh Nodes After having checked that all Mesh Access Points are...

Страница 25: ...stable in 8 steps max 88dBA 10cm Mechanical Colour Blue Dimensions 134mm x 53mm x 26mm HxWxD Weight 135 grams including battery clip Environmental Electromagnetic Immunity EN 61000 4 3 immunity to ele...

Страница 26: ...1KV Input Voltage Current 100 240VAC 50 60Hz 300mA Output Voltage Current 5V DC 1A Max Ripple 200mV Max Max Power 5 Watts Efficiency DOE Level VI and CoC V5 Tier2 Short Circuit Protection Yes Over Vol...

Страница 27: ...unks web based programming CDR reports Configuration Local and remote programming via web based GUI Mechanical Colour Black Material ABS Enclosure Desk or Wall Mounted Dimensions 320mm x 51mm x 200mm...

Страница 28: ...n Yes LED Indicators 9 ACT USB 2 4G 5G LAN A1 to LAN A4 LAN B Antenna 2 No 2 4 5 GHz detachable Dipole RP SMA Male 140mm high Management Web Interface HTTP HTTPS Mechanical Colour White Material ABS E...

Страница 29: ...Doc No FM0855 issue 2 Page 29 24 AMENDMENTS RECORD The table below lists significant changes to this manual Issue Amendments Date 1 First Draft 26 07 19 2 Preliminary issue 31 07 19...

Отзывы: