10. DRAYTEK VIGOR AP 903 ACCESS POINT
One Draytek Vigor AP 903 Access Point (known as the Mesh Root) is connected via its LAN A1 Port to the
Matrix IP-PBX Ethernet Port using a standard Cat5e UTP Patch lead. Up to another seven Access Points
(known as Mesh Nodes) can be deployed and connected wirelessly throughout the building to expand the
WiFi coverage.
Each Access Point requires connection to a local mains supply via a 12V DC plug-top mains adapter
provided with each unit. Access Points can be powered from an additional 12V DC power supply, but
additional site wiring will be required.
*Note: the current rating of the PSU and the conductor size used for
the site wiring will need to be calculated based on the number of Access Points and the length of cable.
Alternatively the Mesh Root can be powered via a PoE switch (LAN A1 Port only).
Draytek Vigor AP 903
WLAN/WPS BUTTON
Not used in this application.
FACTORY RESET BUTTON
This button is used to restore the default settings. When the Access Point is operating (ACT LED blinking)
press and hold the reset button for about 10 seconds until the ACT LED blinks rapidly, release the button
and the Access Point will restart with its factory config. This can take up to 60 seconds.
LAN PORTS
RJ45 Gigabit Ethernet connections for local network devices
–
only LAN A1 is used in this application.
Note: LAN A1 can also be used for powering the Access Point via a PoE connection.
POWER PORT/POWER BUTTON
The bullet plug connector for the 12V DC power adapter is on the bottom left hand side, the power on/off
button is on the bottom right hand side.
WLAN/WPS Button
Surface Mount Enclosure
167 x 107 x 45mm (HxWxD)
2 No. Detachable
RP-SMA Antennas
(138mm high)
Factory Reset Button
5 Gigabit Ethernet
LAN Ports (1 PoE)
Power Port
Status LED indicators
Power on/off Button
USB 2.0 Port
Tynetec Part No.
ZXT963