background image

37

If your Tensioned Advantage with SightLine was ordered as a complete unit, the up and down limits were pre-set by Da-Lite 
at 24". The desired amount of cable drop can be adjusted according to the instructions below. If your screen and roller 
assembly was ordered separately from the case, or if general adjustment is needed, please follow the steps below and refer 
to the Wiring Diagram.

1.   Locate the wall switch and remove the cover plate from 

the wall switch and remove the switch from the junction 

box.

2.   Locate the two tactile buttons on the back of the switch.  

They are black round buttons on silver plates. 

3.   To adjust the down limit switch, press and hold the 

down tactile button until the LED on the back of the 

switch turns solid red. This will put the motor in limit set 

mode. Turn the wall switch over and use the down 

button on the front of the switch. Press and hold the 

down button until the desired down position is reached. 

If you travel too far down, press the up button to move 

the screen upward. If you press and let go of either the 

up or down buttons, the motor will do a small jog in that 

direction for fine adjustment of the screen. Once the 

desired position is reached, turn the switch over; press 

and hold the down tactile button until the LED on back 

of switch blinks red twice. The down limit is now set.

CAUTION: Do not adjust for more than 70” of wire 

drop. At least 2 wraps of wire must remain on the 

roller. This screen comes standard with 0" to 70" of 

wire drop. See the specification data sheet for 

details. 

ATTENTION! LA LONGUEUR DE LA CHUTE DE 

CÂBLE NE DOIT PAS DÉPASSER 170 CM (60 PO). AU 

MOINS DEUX ENROULEMENTS DE CÂBLE DOIVENT 

DEMEURER SUR LE ROULEAU. CET ÉCRAN EST 

LIVRÉ DE SÉRIE AVEC UNE CHUTE DE CÂBLE DE 0 

CM/PO À 170 CM (60 PO). CONSULTEZ LA FICHE 

TECHNIQUE POUR PLUS DE RENSEIGNEMENTS.

NOTE: If the screen is in limit set mode and no buttons 

are pushed for 20 seconds, the LED on the back of the 

wall switch will turn off, the motor will return to run 

mode and no changes will be saved. If this occurs, 

return to step 3 for down limit adjustment or step 4 for 

up limit adjustment.

4.   To adjust the up limit switch, press and hold the up 

tactile button until the LED on the back of the switch 

turns solid green. This will put the motor in limit set 

mode. Turn the wall switch over and use the up button 

on the front of the switch. Press and hold the up button 

until the desired up position is reached. If you travel too 

far up, press the down button to move the screen 

downward. If you press and let go of either the up or 

down buttons, the motor will do a small jog in that 

direction for fine adjustment of the screen. Once the 

desired position is reached, turn the switch over; press 

and hold the up tactile button until the LED on back of 

switch blinks green twice. The up limit is now set.

5.   To test the limit switch settings, press and release the 

up or down buttons on the switch to operate the screen.

6.  Replace the switch and cover plate on the wall.
 

IMPORTANT NOTE: The wall switch is REQUIRED to 

make any limit switch adjustments, even if a third party 

control system is used. Therefore, it is advised to wire 

the switch or provide a 3-conductor connection that is 

accessible.

For Screens with Standard Built-In Low Voltage Control or Optional VPI

SCREEN ADJUSTMENT

UP

STOP

DOWN

BUS

C

O

M

5

V

Front of Wall 

Switch

UP

STOP

DOWN

BUS

C

O

M

5V

LED

Up Limit

Tactile Button

Down Limit

Tactile Button

Back of

Wall Switch

Содержание DA-LITE Tensioned Advantage Series

Страница 1: ...Tensioned Advantage Series USER MANUAL 200076 Rev C ...

Страница 2: ...rol Tensioned Advantage Previously Named Tensioned Advantage Electrol Tensioned Advantage with SightLine Tensioned Advantage Over 14 W with Closure Door Previously Named Tensioned Large Advantage Deluxe Electrol Tensioned Advantage Over 16 W Previously Named Tensioned Large Advantage Electrol 2 13 27 41 51 ...

Страница 3: ...Tensioned Advantage with Closure Door USER MANUAL 200072 Rev C 88585 ...

Страница 4: ...installer s responsibility to make sure the structure to which this component is attached can support the weight of all equipment Reinforce the structure as required before installing the component 7 Use this projection screen only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer Save These Instructions Legrand AV Inc and its affili...

Страница 5: ...ed 1 8 hex key and a 1 4 wrench to remove silver shipping brackets attached to slat and screen case 4 Install electrical connections that apply to your unit Refer to the following diagrams for proper installation The terminal block for the wall switch connections is located under the metal housing surrounding the junction box Remove two screws for access NOTE Use provided knockouts for all electri...

Страница 6: ... preinstalled 7 Test installation by operating the screen several times Be prepared to stop the screen Standard Duty Cycle 1 MIN ON 3 MIN OFF The fabric door rear door will not close until the wall switch is placed in the up position and when the screen motor stops at its limit switch in the up direction CAUTION Excessive continuous operation may cause the motor to overheat If this happens the mot...

Страница 7: ... N effectuez pas de réglage pour obtenir un déroulement supérieur à celui commandé Au moins 1 à 1 2 tour de toile doit être maintenu sur le cylindre Cet écran est doté de série d une bande noire supérieure de 0 cm 0 po ou 5 cm 2 po Consultez la fiche technique pour plus de renseignements Less Screen Drop 1 Raise picture surface approximately two feet above desired level 2 Place operating switch in...

Страница 8: ... Bracket Mounting Method Suggested 3 8 Threaded Rod Not Included Attached to Mounting Bracket 9 1 4 Finished Ceiling Self Trimming Flange 8 3 4 7 1 4 8 75 7 21 8 74 Motor End Variable Position Mounting Brackets 7 1 4 7 5 8 Electrical Junction Box 7 1 4 7 5 8 Case Length TENSIONED ADVANTAGE WITH CLOSURE DOOR INSTALLATION ...

Страница 9: ...HITE WHITE Common Red Up Black Down Green Ground WHITE WHITE Common Red Up Black Down Green Ground WHITE WHITE Common Red Down Black Up Green Ground WHITE WHITE Common Red Down Black Up Green Ground DOWN STOP UP WHITE WHITE Common Red Up Black Down Brown Up Brown Down Blue Common Black Up Black Down Blue Common Blue Common Blue Common Black Up Black Down Brown Down Brown Up Green Yellow Ground Gre...

Страница 10: ...tch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen will not move upward Motor does not hum Motor hums Incorrect line voltage Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line Blown facility fuse Replace facility fuse Tripped facility circuit breaker Reset facility circuit breaker No power to ope...

Страница 11: ...et Fabric hangs crooked Screen not installed properly Check for level and plumb Fabric is damaged Replace fabric Door closes before screen is all the way up Screen up limit out of adjustment Adjust up limit call factory for instructions Door opens but screen does not operate Loose wire Check all wiring and connections Temperature Between 40 1000F 5 400C Relative Humidity 30 to 70 non condensing Al...

Страница 12: ... at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to Da Lite transportation expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepa...

Страница 13: ...Tensioned Advantage USER MANUAL 200069 Rev C 84215 ...

Страница 14: ...t not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support the weight of all equipment Reinforce the structure as req...

Страница 15: ...uded Attached To Mounting Bracket Self Trimming Flange Finished Ceiling 7 3 4 7 3 4 6 1 16 6 3 8 3 7 16 7 7 16 6 7 16 Method 1 Method 2 9 1 4 Table 1 Case Length Number of Mounting Brackets 97 25 and Under 2 Over 97 25 to 182 3 Over 182 to 212 75 4 Table 2 Case Length Number of Mounting Brackets 182 and Under 2 Over 182 to 212 75 3 TENSIONED ADVANTAGE SUGGESTED METHODS OF INSTALLATION Audience Sid...

Страница 16: ...ive foam covering the outside of the case 1 2 and 5 16 Open Wrench or Socket Driver 1 8 Hex Key included 5 For shipping purposes foam is also inserted between the roller brackets and end caps Figure 1 Remove these foam blocks from the ends 6 Remove the hanger brackets from the top of the case using a 1 2 wrench Do not discard the hardware it will be used during case installation to re attach the h...

Страница 17: ...sert the motor end square shaft into the motor end bracket junction box end and secure with the cotter pin Figure 2 5 Moving to the pin end of the case slide the pin end bracket until the hole fits securely over the pin and secure with the cotter pin Tighten the 1 4 20 nuts on the pin end bracket securely Figure 2 6 Complete electrical hook up by snapping motor wire connector into case connector F...

Страница 18: ...a duty cycle of 1 min on 3 min off Rated torque of model DL45EQ 6 28 is 6 N m with a duty cycle of 1 min on 3 min off Motor is intended for use in Da Lite screens incorporating a 3 00 and 3 25 roller diameter 1 Make sure motor collar is on motor 2 Collars keyway must line up with the key on the motor 3 Secure motor drive wheel on output shaft of motor and insert retaining clip SCREEN AND ROLLER AS...

Страница 19: ...f the supplied RJ 14 6P4C cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board UP STOP DO WN BUS COM 5V Power Input 120VAC 60Hz Green Ground Ground Must be Connected to Building Ground Black Hot White Common Power Wire Data Cable RJ 45 Jack RJ 14 Jack Connection to Wall Switch RJ 14 Jack RJ 14 Pin Outs Tab Is Facing ...

Страница 20: ...ed in place of the supplied RJ 14 6P4C cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible UP ...

Страница 21: ...it switch adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Common Brown Hot Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Down on Tab to Insert Wire TENSIONED ADVANTAGE INSTALLATION FOR 2...

Страница 22: ...ger output to the length required to reach the VPI NOTE When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provid...

Страница 23: ...ges will be saved If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment NOTE All screens except Parallax standard with 12 black drop at the top Screens with Parallax surface standard with 2 of black drop at the top 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the mo...

Страница 24: ...n up and down wires will be a stop command Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 Press UP button on screen switch and screen will retract upward into case Up Button Stop Button Down Button Up Button Down Button European Style Wall...

Страница 25: ...or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen does not stop at correct position Limit switch out of adjustment See Screen Adjustment section Noise NOTE Screen will operate with a low pitched hum Squeaking rubber end plug rubbing ...

Страница 26: ...r damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by s...

Страница 27: ...Tensioned Advantage with SightLine USER MANUAL 210747 Rev A DL15520 ...

Страница 28: ...t not recommended by the manufacturer may cause a risk of fire electric shock or injury to persons 12 Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support the weight of all equipment Reinforce the structure as req...

Страница 29: ...aded Rod Not Included Attached To Mounting Bracket Self Trimming Flange Finished Ceiling 7 3 4 7 3 4 6 1 16 6 3 8 3 7 16 7 7 16 6 7 16 Method 1 Method 2 9 1 4 Table 1 Case Length Number of Mounting Brackets 97 25 and Under 2 Over 97 25 to 170 3 Table 2 Case Length Number of Mounting Brackets 170 and Under 2 TENSIONED ADVANTAGE WITH SIGHTLINE SUGGESTED METHODS OF INSTALLATION Audience Side ...

Страница 30: ...ive foam covering the outside of the case 1 2 and 5 16 Open Wrench or Socket Driver 1 8 Hex Key included 5 For shipping purposes foam is also inserted between the roller brackets and end caps Figure 1 Remove these foam blocks from the ends 6 Remove the hanger brackets from the top of the case using a 1 2 wrench Do not discard the hardware it will be used during case installation to re attach the h...

Страница 31: ...sert the motor end square shaft into the motor end bracket junction box end and secure with the cotter pin Figure 2 5 Moving to the pin end of the case slide the pin end bracket until the hole fits securely over the pin and secure with the cotter pin Tighten the 1 4 20 nuts on the pin end bracket securely Figure 2 6 Complete electrical hook up by snapping motor wire connector into case connector F...

Страница 32: ...a duty cycle of 1 min on 3 min off Rated torque of model DL45EQ 6 28 is 6 N m with a duty cycle of 1 min on 3 min off Motor is intended for use in Da Lite screens incorporating a 3 00 and 3 25 roller diameter 1 Make sure motor collar is on motor 2 Collars keyway must line up with the key on the motor 3 Secure motor drive wheel on output shaft of motor and insert retaining clip SCREEN AND ROLLER AS...

Страница 33: ... to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board UP STOP DO WN BUS COM 5V Power Input 120VAC 60Hz Green Ground Ground Must be Connected to Building Ground Black Hot White Common Power Wire Data Cable RJ 45 Jack RJ 14 Jack Connection to Wall Switch RJ 14 Jack RJ 14 Pin Outs Tab Is Facing Down Supplied RJ 14 6P4C cable ...

Страница 34: ...lace of the supplied RJ 14 6P4C cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible UP STOP DO...

Страница 35: ...h adjustments Therefore it is advised to wire the limit adjustment switch or provide a 3 conductor connection that is accessible Power Input 220VAC 50Hz Green Yellow Ground Blue Common Brown Hot Power Wire Data Cable RJ 45 Jack Black Down White Common Red Up Red Black White Inputs Output Black Down White L Common Red Up Push Down on Tab to Insert Wire TENSIONED ADVANTAGE WITH SIGHTLINE INSTALLATIO...

Страница 36: ...ger output to the length required to reach the VPI NOTE When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provid...

Страница 37: ... DEUX ENROULEMENTS DE CÂBLE DOIVENT DEMEURER SUR LE ROULEAU CET ÉCRAN EST LIVRÉ DE SÉRIE AVEC UNE CHUTE DE CÂBLE DE 0 CM PO À 170 CM 60 PO CONSULTEZ LA FICHE TECHNIQUE POUR PLUS DE RENSEIGNEMENTS NOTE If the screen is in limit set mode and no buttons are pushed for 20 seconds the LED on the back of the wall switch will turn off the motor will return to run mode and no changes will be saved If this...

Страница 38: ...n up and down wires will be a stop command Operation Limit Adjustment Wall Switch 1 Press DOWN button on screen switch and screen will deploy out of case in downward direction 2 Press STOP button on screen switch and screen will stop if in movement 3 Press UP button on screen switch and screen will retract upward into case Up Button Stop Button Down Button Up Button Down Button European Style Wall...

Страница 39: ...or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen does not stop at correct position Limit switch out of adjustment See Screen Adjustment section Noise NOTE Screen will operate with a low pitched hum Squeaking rubber end plug rubbing ...

Страница 40: ...r damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by s...

Страница 41: ...Tensioned Advantage Over 14 W with Closure Door USER MANUAL 200073 Rev C 35898 ...

Страница 42: ...riations nor does it provide for every possible contingency in connection with the installation or use of the products described herein The content herein is subject to change without notice or obligation of any kind To the maximum extent permitted by applicable law Legrand AV makes no representation or warranty expressed or implied regarding the information contained herein Furthermore Legrand AV...

Страница 43: ...remove silver shipping brackets attached to slat and screen case 4 Install electrical connections that apply to your unit Review the wiring diagrams for proper installation 1 Carefully unpack screen and remove outer wrapping from case 2 Make sure to recheck measurements of screen location before installation PLEASE NOTE Motor Operator Projection Screen Models LADT LADDT LAD and LADD must be instal...

Страница 44: ...rimming Flange 9 1 8 13 1 8 12 3 16 11 7 16 11 Door Roller Screen Roller Closing Door Access Door Audience Side Self Trimming Flange 2 5 16 Electrical Junction Box 10 10 11 11 Case Length Variable Position Mounting Brackets 10 13 16 TENSIONED ADVANTAGE OVER 14 W WITH CLOSURE DOOR INSTALLATION ...

Страница 45: ...n Ground White Common Red Up Black Down Green Ground 220V Wiring Diagram NOTE Electrical connections on left end of case Use provided knockouts for all electrical connections DO NOT drill additional holes into screen case or end cap NOTE 20 24AWG Wire Recommended For Connecting Wall Switch to the Dual Motor Controller Power Input 220VAC 50HZ Front of Wall Switch Back of Wall Switch Optional RF or ...

Страница 46: ...e connectors into case connectors 8 Return to motor end and insert safety clip over casting bracket to secure motor end CAUTION Do not cut tape on fabric with a knife or any sharp tool Remove by hand ATTENTION Ne coupez pas le ruban adhésif sur la toile avec un couteau ou un outil tranchant Retirez à la main 9 Carefully remove tape strips securing picture surface around roller Slat should move fre...

Страница 47: ... not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller This screen comes standard with 12 black at the top ATTENTION N effectuez pas de réglage pour obtenir un déroulement supérieur à celui commandé Au moins 1 à 1 2 tour de toile doit être maintenu sur le cylindre Ce écran est doté de série d une bande noire supérieure de 30 5 cm 12 po Less Screen ...

Страница 48: ...tch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen will not move upward Motor does not hum Motor hums Incorrect line voltage Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line Blown facility fuse Replace facility fuse Tripped facility circuit breaker Reset facility circuit breaker No power to ope...

Страница 49: ...llation instructions Noise NOTE Screen will operate with a low pitched hum Buzzing noise Adjust door limit switch too far down Gear noise Replace motor assembly Coasting Defective brake Replace motor assembly Roller displaced from mounting bracket Pin end slipped out of nylon bearing Realign pin end bracket Fabric hangs crooked Screen not installed properly Check for level and plumb Fabric is dama...

Страница 50: ...r damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by s...

Страница 51: ...Tensioned Advantage Over 16 W USER MANUAL 200074 Rev C 35890 ...

Страница 52: ...ossible contingency in connection with the installation or use of the products described herein The content herein is subject to change without notice or obligation of any kind To the maximum extent permitted by applicable law Legrand AV makes no representation or warranty expressed or implied regarding the information contained herein Furthermore Legrand AV assumes no responsibility for accuracy ...

Страница 53: ...ecessary adjust hanger brackets with a 3 4 open wrench or socket driver 3 4 Open Wrench or Socket Driver 1 8 Hex Key included TOOLS REQUIRED FOR INSTALLATION PRE INSTALLATION CASE INSTALLATION 1 The case provides multiple attachment points for bolts cables or threaded rod Page 4 shows threaded rod installed The variable position mounting bracket may be located anywhere along the length of the case...

Страница 54: ... the motor on the left side The limit switches should be facing down Line up the head of the motor with the motor attachment bracket 7 Complete electrical hook up by snapping motor 1 3 wire connectors into case connectors Figure 2 8 Return to motor end and insert safety clip over casting bracket to secure motor end 9 Carefully remove tape strips securing picture surface around roller Slat should m...

Страница 55: ...l Junction Box Screen Roller Access Door Audience Side Self Trimming Flange 2 3 16 Suggested 1 2 Threaded Rod Not Included Attached to Mounting Bracket Finished Ceiling Self Trimming Flange 12 3 16 13 1 8 11 9 1 8 11 7 16 10 15 16 TENSIONED ADVANTAGE OVER 16 W INSTALLATION ...

Страница 56: ...e operating switch in off position 3 Turn the white down limit switch Figure 4 one quarter turn clockwise Test by raising picture surface approximately two feet then lower again Repeat until desired picture surface position is attained CAUTION Adjusting the down limit switch for less drop by more than 6 can cause the screen surface to lose proper tensioning ATTENTION Le fait d ajouter ne déroulez ...

Страница 57: ...TTENTION NE UTILISEZ PAS l interrupteur à bascule fourni avec l écran Le tableau de contrôle basse tension sera endommagé Eye Port Plug IR or RF Remote Here Power Input 120VAC 60Hz Black Hot White Common White Common Black Down Red Up Green Ground Screen Motor Red Up White Common Black Down Front of Wall Switch Back of Wall Switch Green Ground White Common Black Down Red Up Green Ground 120V WIRIN...

Страница 58: ...Black Blue Common Brown Down Black Up Green Yellow Ground Wire Nut Wire Nut 240V WIRING DIAGRAM NOTE 20 24 AWG wire recommended for connecting wall switch to low voltage controller CAUTION Do not use 3 position high voltage rocker switch with this unit This will damage the low voltage control board ATTENTION NE UTILISEZ PAS l interrupteur à bascule fourni avec l écran Le tableau de contrôle basse ...

Страница 59: ...or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Screen does not stop at correct position Limit switch out of adjustment See Screen Adjustment section Noise NOTE Screen will operate with a low pitched hum Squeaking rubber end plug rubbing ...

Страница 60: ...ion expenses to and from Da Lite are payable by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHAN...

Страница 61: ...ective owners All patents are protected under existing designations Other patents pending FOR YOUR IMAGE legrandav com USA 866 977 3901 av da lite support legrand com CANADA 877 345 4329 av da lite support legrand com EMEA 31 495 580 840 av emea sales legrand com APAC 852 2145 4099 av asia sales legrand com C2G Chief Da Lite Luxul Middle Atlantic Vaddio Wiremold LEGRAND AV COMMERCIAL BRANDS ...

Отзывы: