34
RJ-45
Receptacle
RJ-14
Output
RJ-14
Inputs
Up (Dry Contact)
Down (Dry Contact)
Common (Both)
Bus (Bus)
5V (Bus)
UP
STOP
DOWN
BUS
C
O
M
5
V
Front of
Wall Switch
Bus
UP
STOP
DOWN
BUS
C
O
M
5V
LED
Up Limit
Tactile Button
Down Limit
Tactile Button
Back of
Wall Switch
RJ-25 Pin-Outs
(Tab Is Facing Down)
Bus (RP Data)
+12V
RQ Clock
RQ Data
+5V
Ground
Yellow
Red
Green
Black
White
Blue
RJ-45 Pin-Outs
(Tab Is Facing Down)
+12V
Manual 2
Ground
Manual 1
RQ Clock
Bus (RP Data)
RQ Data
+5V
Blue
Green
Yellow
Red
Black
Orange
Purple
Brown
220V Wiring Diagram with Operation & Limit Adjustment
Wall Switch
3-conductor 20–24 gauge wire can be used in place of the
supplied RJ-14 6P4C cable to connect the wall switch.
Connect the BUS terminals on the wall switch to the
corresponding BUS terminals on the splitter board.
IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 3-conductor connection that is accessible.
UP
STOP
DOWN
BUS
C
O
M
5V
Power Input 220VAC / 50Hz
Green / Yellow (Ground)
Blue (Common)
Brown (Hot)
Power
Wire
Data
Cable
RJ-45 Jack
RJ-14 Jack
(Connection to
Wall Switch)
RJ-14
Jack
RJ-14 Pin-Outs
(Tab Is Facing Down)
Bus (RP Data)
RQ Data
+5V
Ground
White
Green
Red
Black
Standard RJ-25 6P6C can be used in place of RJ-14
cable (Only center 4 pins used)
Supplied RJ-14 6P4C cable
TENSIONED ADVANTAGE WITH SIGHTLINE
INSTALLATION FOR 220V SCREENS
Содержание DA-LITE Tensioned Advantage Series
Страница 1: ...Tensioned Advantage Series USER MANUAL 200076 Rev C ...
Страница 3: ...Tensioned Advantage with Closure Door USER MANUAL 200072 Rev C 88585 ...
Страница 13: ...Tensioned Advantage USER MANUAL 200069 Rev C 84215 ...
Страница 27: ...Tensioned Advantage with SightLine USER MANUAL 210747 Rev A DL15520 ...
Страница 41: ...Tensioned Advantage Over 14 W with Closure Door USER MANUAL 200073 Rev C 35898 ...
Страница 51: ...Tensioned Advantage Over 16 W USER MANUAL 200074 Rev C 35890 ...