The uncapping device is provided with two control panels, the main control unit (fig.2) is placed on the right
side of the machine, the operating panel (fig.1) is placed in the front position, convenient for the operator.
Before plugging the uncapping machine into a line power socket, make sure that the main switch (fig. 2 - G) is
set to 'O'.
Plug the DV4 uncapping machine into a power socket.
Make sure that the mushroom-head emergency button (fig. 1-A) and the switch on the main control panel (fig.
2-F) have not been operated, then turn the main switch (fig. 2 - G) to
‘0’.
Set the thermostat (fig. 1-E) as illustrated in paragraph '2.1
Instructions for thermoregulator use' of this manual.
The default temperature setting - which on average has been found
correct - is 80/90°C.
Control knife heating by actuating the
selector switch ‘Heating’ (fig. 1
- B) then wait a few seconds to allow the knives to heat up to the pre-
set temperature.
To adjust the knives, operate on the lever.
The lever could also serve to widen the knives in case of emergency, to release a frame which got stuck.
Place the frames on the (stationary) chain perpendicularly to the chain
(fig. 3) and cause the chain to run towards the machine inlet so that
9/10 frames can be added.
Turn the selector switch (Fig. 1-
C) to the right, in its ‘Start’ position, to
control the forward movement of the chain and the knives.
It is also possible to load the frames when the uncapping machine has
been started, i.e. when the chain is moving, in a continuous manner.
If a frame gets stuck, turn the selector switch (fig. 1 - C) to
a central position to stop the chain.
It is possible to rotate the chain in the opposite direction, by rotating the selector switch (fig. 1-C) to the left,
for pulse operation.
At the end of the work you must disconnect the machine by turning the main switch (fig. 2-G) to position '0'.
In case of danger, hit the emergency button (
fig. 1 item
A or
fig. 2 item
F).
The emergency stop shall prevail over all other functions and operations.