UPS fail to start when operate 
“On” key 

Pressing time too short 

Please press the power key more than 2 

seconds to start the UPS. 

The input connection is 

not ready or 

UPS internal battery 

disconnect   

Please connect the input well, if the battery 

voltage is too low, please disconnect the 

input and start the UPS with no-load. 

UPS internal system 

fault   

Please contact the supplier. 

Back up time become short 

Battery undercharge 

Please keep the UPS battery recharging 

more than 3 hours   

UPS overload 

Please check the load level and 

disconnect the noncritical devices, 

Battery maturing, 

capacity descend 

Please change new battery, contact your 

supplier to get the new battery and spare 

parts. 

UPS doesn’t have any power go 
through even main power on 

UPS input breaker 

disconnects 

Please reset the circuit breaker by manual. 

Attention:

 When the output is short-circuited, the action of the protection of the UPS will show up. Before 

turning off the UPS, please make sure to disconnect the entire load and cut off the AC mains power supply, 

otherwise will make the AC input short-circuit. 

7. Attention of battery disposal 

Please take off metal objects, such as, ring, watch and the likes before dealing with batteries. 

If you want to replace the battery cable, please purchase it from our local service center or distributors to 

avoid fever and lighter which can cause fire from inadequate power capacity. 

Don’t dispose the battery or battery pack by fire, it will explode. 

Don’t damage or open the battery case, the overflow battery electrolyte has a strong toxicity which will do 

harm to humans. 

Please avoid short circuit which may cause fire or electric shock. 

Please  check  the  battery  voltage  before  touching.  Otherwise,  it  will  form  a  high  voltage  environment 

between BAT. There will be high voltage between the terminals and the ground when battery circuits and 

the input voltage loop is not isolated. 

8. Network communication 

This  series  UPS  offer  intelligent  network  interface  with  a  dedicated  Ethernet  card  (optional  accessory),  to 

realize network communications. For more details, please contact our local distributor or service center. 

9. Communication interface introduction 

The UPS communicates with PC via analog relay joint and serial interface (RS232). The former transmits the 
input  power  and  UPS  status  to  PC  by  choosing  “on”  or  “off”  states  of  transistor.  The  latter  offers 
communication interface serials with PC to monitor input power and UPS status information, and control the 

UPS also. 

Note:

 The communicating function is only realizable with the specific communicating cable from the supplier. 

RS232 interface is set as below: 

Содержание 1-1 Series

Страница 1: ...using our products Please strictly obey all the instructions in this manual and pay attention to all the warning and operation information It is not advisable to install or operate the machine before...

Страница 2: ...S if any damage in transport If find damaged or parts missing do not power on please turn to the carrier and dealer To determine whether this UPS is the model you want to buy Check the model name show...

Страница 3: ...ry over 8 hours before used Once the AC mains power energizes the UPS it will automatically charge the battery Without prior charging UPS output remains as usual but with shorter back up time than nor...

Страница 4: ...E 1 2 5 V A C 3 5 A I N P U T O U T P U T S O C K E T T E L M O D E M F A X O U T I N R S 2 3 2 U S B E P O I N T E L L I G E N T S L O T O U T P U T L N G N D R E S E T R E S E T T O 7 2 V D C 4 0 A...

Страница 5: ...10mm2 10KVAH 10mm2 10mm2 10mm2 10mm2 10mm2 Note The cable for 6KVAS 6KVAS should withstand over 40A current It is recommended to use 10AWG or thicker wire for safety and efficiency The cable for 10KV...

Страница 6: ...er in OFF position and then install the battery pack Pay highly attention to the rated battery voltage marked on the rear panel if you want to change the numbers of the battery pack please make sure y...

Страница 7: ...nnecting N1 L2 it becomes three outputs one high voltage 208v 220v 230v 240V at L1 N2 two low voltage outputs 100v 110v 115v 120V at L1 N1 and L2 N2 However there is a limit for current rating at L1 N...

Страница 8: ...ls Correct installation procedure is highly vital or else probable electric shock will arise Users are strictly required to follow the below procedure Connect battery in correct way and make sure the...

Страница 9: ...function INQUIRING KEY Non function setting mode Press and hold or for more than half a second less than 2 seconds display the items orderly Press and hold for more than 2 seconds Circularly and order...

Страница 10: ...ted B The fan icon is for fan working indication when fan normally runs the icon will display rotation if the fan is not connected or faulty the icon blinks C Press the mute button under the battery m...

Страница 11: ...S are working in battery mode 3 4 2 Turn Off operation i Turn off the UPS in line mode Press and hold the OFF key for more than half a second to turn off the UPS and inverter After UPS shutting down L...

Страница 12: ...erface Press and hold the function setting key for more than 2 seconds then come to setting interface press and hold the function setting key for more than half a second less than 2 seconds select the...

Страница 13: ...is 220V Confirm the output voltage setting interface After selecting numerical value press and hold the function setting for more than half a second less than 2 seconds Now the OPU setting function is...

Страница 14: ...ce Press and hold function setting key for more than half a second less than 2 seconds exit from the setting interface and return to main interface 3 7 Parameters inquiring operation Press and hold th...

Страница 15: ...pproximately reckoned according to the battery voltage Press and hold the inquiring key for more than 2 seconds LCD begins to display the items circularly and orderly which transfer to another every 2...

Страница 16: ...w LED are on When the input mains meets the input range of the ECO mode and the ECO function is on the UPS will works in ECO mode If input AC mains exceed the range of ECO several times within one min...

Страница 17: ...le for working status S N Working status LED on Front panel Alarm beep Note Normal Battery Bypass Fault 1 Inverter mode mains power Mains power voltage N Mains power high low voltage protection switch...

Страница 18: ...arning for bypass mode overload One beep 2 sec 7 Fans fault fan icon One beep 2 sec 8 Faults mode Long beep LED indicator lights long time LED indicator flicker LED indicator status depends on other c...

Страница 19: ...Turn of the UPS and disconnect all the load make sure there no any fault or internal short circuit of the load And then restart the UPS if failure still please contact the supplier Fault LED on audibl...

Страница 20: ...ries If you want to replace the battery cable please purchase it from our local service center or distributors to avoid fever and lighter which can cause fire from inadequate power capacity Don t disp...

Страница 21: ...cancel Turn on Overload Turn off Battery inspection Standby or Shutdown Repeat AC Display screen repeat key DC Battery Appendix 3 Specification Sheet 1 3KVA Rated Capacity 1KVA 1 5KVA 2KVA 3KVA Input...

Страница 22: ...d rate 1Hz s Total voltage harmonic distortion Full linear load 3 Full nonlinear load 5 Battery Battery type Sealed lead acid maintenance free battery Quantity 2 3 4 4 6 6 8 DC voltage 24V 36V 48V 48V...

Страница 23: ...3 mins 125 150 30 secs 150 100ms Voltage accuracy 0 2 Load crest 3 1 From AC mode to BAT mode 0ms transfer time From BAT mode to AC mode 0ms transfer time Efficiency Mains mode 92 full load BAT mode 9...

Страница 24: ...Isolated 10KVA 10KVA Isolated Containing isolation transformers No Yes No Yes Dimension W D H Long 262 514 455 262 650 735 262 514 455 262 650 735 Standard 262 514 735 262 650 735 262 514 735 262 650...

Страница 25: ...ftware and hardware on the network such as running HP open view IBM net view SUN net manager and other operation system UPS is with function login on internet which can supply information of UPS statu...

Отзывы: