background image

   

 

LED 

                                     

  Bracket 

Reset button 

 
 
 

Button:   

 

Short  press  reset  button  into  learning  mode,  then  the  sensor  can  inclusion  or 
exclusion from the Z-Wave network. 

 

Hold  the  key  for  5s  to  reset  the  sensor,  after  reset,  Sensor  will  send 
“Device_Reset_Locally”  to  the  main  controller  and  exclude  from  the  Z-Wave 
network  when  the  Button  is  released,  this  procedure  will  reset  the  Sensor  to 
factory default. 

 

Short  press  button  for  3  times  then  the  sensor  sending  wake  up  notificati
on  to  gateway, 

and  LED  will  fast  blink  when  sending  data,  send  over  then  the  L

ED  turn  off.

 
 

Specification 

Detection angle 

80 degrees 

Detection distance 

8 meters / 26.25 feet 

Содержание 7CA-SS-VE-C0

Страница 1: ...LEEDARSON Motion sensor Pet Immunity Z Wave 7CA SS VE C0 We build your success in IoT ...

Страница 2: ...n be adapted to EU 868 42Mhz or US 908 42MHz If you want your Motion Sensor to be a security device that use secure encrypted message to communicate in a Z Wave network then a security enabled Z Wave controller is needed The motion sensor can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operate...

Страница 3: ...end Device_Reset_Locally to the main controller and exclude from the Z Wave network when the Button is released this procedure will reset the Sensor to factory default Short press button for 3 times then the sensor sending wake up notificati on to gateway and LED will fast blink when sending data send over then the L ED turn off Specification Detection angle 80 degrees Detection distance 8 meters ...

Страница 4: ...amper YES Low power alarm YES Certifications CE FCC Z Wave 3 Features Capabilities Supports pet immunity up to 80 lbs 36 kgs Use PIR Fresnel lens technology Easy installation with bracket Low battery alarm Equipped with an anti tamper switch that reports any tampering 4 Installation Position and Notes 1 Installation position should be chosen at the area which the bass by will be across try to make...

Страница 5: ...ch as the wall will shorten the distance of wireless communication 5 This device can be mounted on the wall only it cannot be installed on the ceiling 5 Product Installation Adding the device as accessories install it according to the diagram below Choose the installation location on the wall fix the bracket by screw or 3M adhesion tape on the wall Take off the bracket in the back and draw out the...

Страница 6: ...Led will off Note User should follow the procedure in the section below if the controller does not support SmartStart inclusion Short press button three time Add the Motion Sensor into the Z Wave network 5 Power on your Motion Sensor and let your Z Wave controllerinto add inclusion mode 6 3 consecutive clicks in 1 5 seconds the Motion Sensor will send out a node info security CC in command class l...

Страница 7: ...is released this procedure will reset the sensor to factory default Motion is triggered In the network Send Notification report and Sensor multilevel report and Basic set Setup configuration parameter 0x0E to 0x01 and the LED will be turn on 0 2 second Not in the network Motion sensor is disable Tamper switch is triggered In the network Send Notification report and the LED will be turn on 0 2 seco...

Страница 8: ... is 20 25 the target of the test is 77kg 10kg weight and 1 71m 0 3m height the target of the test across movement speed is 4m s 0 15m s 6 In order to prevent the PIR sensor s abnormal fault please don t mounting and operating sensor in the bellow conditions Firstly product mounting should prevent installed in the air flow environment such as in front of the door window heater air conditioner and s...

Страница 9: ...t COMMAND_CLASS_ASSOCIATION_GRP_INFO Frame COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V3 COMMAND_CLASS_WAKE_UP COMMAND_CLASS_CONFIGURATION_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 Included S2 Non Secure Node Info COMMAND_CLASS_ZWAVEPLUS_INFO Frame COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CL...

Страница 10: ...05 Command Class COMMAND_CLASS_BATTERY 0x80 Command BATTERY_REPORT 0x03 Command Class COMMAND_CLASS_DEVICE_RESET_LOCALLY 0x5A Command DEVICE_RESET_LOCALLY_NOTIFICATION 0x01 Command Class COMMAND_CLASS_SENSOR_MULTILEVEL_V5 0x31 Command SENSOR_MULTILEVEL_REPORT 0x05 Group 2 Command List Support Command Class COMMAND_CLASS_BASIC 0x20 Command BASIC_SET 0x01 Notification Commands Notification Type Noti...

Страница 11: ...BATTERY_NOW 0x00 NO_EVENT LIGHET_ALARM 0x14 0x00 NO_EVENT 0x01 LIGHETSENSOR_ALARM_DETECTED Configuration Set Command Class Command Format 7 6 5 4 3 2 1 0 Command Class COMMAND_CLASS_CONFIGURATION Command CONFIGURATION_SET Parameter Number Default Reserved Size Configuration Value 1 MSB Configuration Value 2 Configuration Value n LSB ...

Страница 12: ... 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities BasicReverse BasicValue 0x0F 15 0 0X00 1 0X01 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities PirSensitivity PirSensitivitySet 0x10 16 9 0X09 10 0X0A 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities PirPetImmunity PirPetImmunitySet 0x11 17 0 0X00 1 0X01 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alter...

Страница 13: ...end the basic set with 0xFF Only support 0x00 and 0x01 values as valid value 0x10 16 Motion detection sensitivity level is a value between 1 and 10 This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle 1 Lowest Motion Sensitivity 10 Highest Motion Sensitivity 0x11 17 Enable disable pet immunity mode This feature is lens de...