background image

 

Short press 

button one    time 

In the network: 

Send Wake up notification, and LED will fast blink when 

sending data, send over then the LED turn off. 

 

Not In the network: 

NOP. 

 
 
 
 

Press and hold 

more than 5 

seconds 

Reset Motion Sensor to factory default. 

 

1.  Triggering this action, in 5 seconds LED will be accelerate blink. 

After 5 seconds, the LED will remain on until the key is released. 
Motion Sensor will send “Device_Reset_Locally” to the main 
controller and exclude from the Z-Wave network when the button is 

released, this procedure will reset the sensor to factory default. 

2. 

Please use this procedure only when the network primary controller is 

missing or otherwise inoperable. 

3. 

When not in the network

,

 triggering this action, in 5 seconds LED will 

be accelerate blink red. After 5 seconds, the LED will remain on red 

until the key is released. this procedure will reset the sensor to factory 

default. 

 

Motion is 

triggered 

In the network: 

Send Notification report and Sensor multilevel report and 

Basic set (Setup configuration parameter 0x0E to 0x01), and the LED will 

be turn on 0.2 second. 

Not in the network:

 Motion sensor is disable. 

 

Tamper switch is 

triggered 

In the network: 

Send Notification report, and the LED will be turn on 0.2 

second. 

Not in the network: 

Tamper switch is disable. 

 

6.2

 

 

Caution:

 

 

This device complies with Part 15 of the FCC rules. Operation is subject to the following 

two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation. 

 

Changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate the equipment. 

 
Hereby, Corporation declares that this device is in compliance with the essential 

requirements and other relevant provisions of Directive 2014/53/EU 

 
 

Содержание 7CA-SS-VE-C0

Страница 1: ...LEEDARSON Motion sensor Pet Immunity Z Wave 7CA SS VE C0 We build your success in IoT ...

Страница 2: ...n be adapted to EU 868 42Mhz or US 908 42MHz If you want your Motion Sensor to be a security device that use secure encrypted message to communicate in a Z Wave network then a security enabled Z Wave controller is needed The motion sensor can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operate...

Страница 3: ...end Device_Reset_Locally to the main controller and exclude from the Z Wave network when the Button is released this procedure will reset the Sensor to factory default Short press button for 3 times then the sensor sending wake up notificati on to gateway and LED will fast blink when sending data send over then the L ED turn off Specification Detection angle 80 degrees Detection distance 8 meters ...

Страница 4: ...amper YES Low power alarm YES Certifications CE FCC Z Wave 3 Features Capabilities Supports pet immunity up to 80 lbs 36 kgs Use PIR Fresnel lens technology Easy installation with bracket Low battery alarm Equipped with an anti tamper switch that reports any tampering 4 Installation Position and Notes 1 Installation position should be chosen at the area which the bass by will be across try to make...

Страница 5: ...ch as the wall will shorten the distance of wireless communication 5 This device can be mounted on the wall only it cannot be installed on the ceiling 5 Product Installation Adding the device as accessories install it according to the diagram below Choose the installation location on the wall fix the bracket by screw or 3M adhesion tape on the wall Take off the bracket in the back and draw out the...

Страница 6: ...Led will off Note User should follow the procedure in the section below if the controller does not support SmartStart inclusion Short press button three time Add the Motion Sensor into the Z Wave network 5 Power on your Motion Sensor and let your Z Wave controllerinto add inclusion mode 6 3 consecutive clicks in 1 5 seconds the Motion Sensor will send out a node info security CC in command class l...

Страница 7: ...is released this procedure will reset the sensor to factory default Motion is triggered In the network Send Notification report and Sensor multilevel report and Basic set Setup configuration parameter 0x0E to 0x01 and the LED will be turn on 0 2 second Not in the network Motion sensor is disable Tamper switch is triggered In the network Send Notification report and the LED will be turn on 0 2 seco...

Страница 8: ... is 20 25 the target of the test is 77kg 10kg weight and 1 71m 0 3m height the target of the test across movement speed is 4m s 0 15m s 6 In order to prevent the PIR sensor s abnormal fault please don t mounting and operating sensor in the bellow conditions Firstly product mounting should prevent installed in the air flow environment such as in front of the door window heater air conditioner and s...

Страница 9: ...t COMMAND_CLASS_ASSOCIATION_GRP_INFO Frame COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V3 COMMAND_CLASS_WAKE_UP COMMAND_CLASS_CONFIGURATION_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 Included S2 Non Secure Node Info COMMAND_CLASS_ZWAVEPLUS_INFO Frame COMMAND_CLASS_TRANSPORT_SERVICE COMMAND_CL...

Страница 10: ...05 Command Class COMMAND_CLASS_BATTERY 0x80 Command BATTERY_REPORT 0x03 Command Class COMMAND_CLASS_DEVICE_RESET_LOCALLY 0x5A Command DEVICE_RESET_LOCALLY_NOTIFICATION 0x01 Command Class COMMAND_CLASS_SENSOR_MULTILEVEL_V5 0x31 Command SENSOR_MULTILEVEL_REPORT 0x05 Group 2 Command List Support Command Class COMMAND_CLASS_BASIC 0x20 Command BASIC_SET 0x01 Notification Commands Notification Type Noti...

Страница 11: ...BATTERY_NOW 0x00 NO_EVENT LIGHET_ALARM 0x14 0x00 NO_EVENT 0x01 LIGHETSENSOR_ALARM_DETECTED Configuration Set Command Class Command Format 7 6 5 4 3 2 1 0 Command Class COMMAND_CLASS_CONFIGURATION Command CONFIGURATION_SET Parameter Number Default Reserved Size Configuration Value 1 MSB Configuration Value 2 Configuration Value n LSB ...

Страница 12: ... 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities BasicReverse BasicValue 0x0F 15 0 0X00 1 0X01 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities PirSensitivity PirSensitivitySet 0x10 16 9 0X09 10 0X0A 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alters capabilities PirPetImmunity PirPetImmunitySet 0x11 17 0 0X00 1 0X01 0 0X00 1 NOT Read only UNSIGNED _INTEGER Will alter...

Страница 13: ...end the basic set with 0xFF Only support 0x00 and 0x01 values as valid value 0x10 16 Motion detection sensitivity level is a value between 1 and 10 This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle 1 Lowest Motion Sensitivity 10 Highest Motion Sensitivity 0x11 17 Enable disable pet immunity mode This feature is lens de...

Отзывы: