![Lectrotab ELECTROMECHANICAL TRIM TAB SYSTEMS Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/lectrotab/electromechanical-trim-tab-systems/electromechanical-trim-tab-systems_operation-and-installation-manual_1866731009.webp)
Oval (SETR) Switch Wiring
Fig. 5
Oval (SETR-61) Switch Installation
1.
The Oval control switch has LED indicators to show tab angle. For dual station applications, an SR
cable for each Oval must be used. For dual station, dual actuators per tab applications or
programming information, visit
www.lectrotab.com
under Products or Technical Library/Technical
Manuals or Wiring Diagrams.
2.
If the W4-** cable is used to connect the switch to actuators, route the cut cable end from the Oval
switch to the transom terminal strip. The push-
on terminal end of the 20’ (6.1m), 4
-conductor, 14
AWG (2.08mm sq.) cable connects to the Oval switch (KA Kits), or route the longer 23’ (7m)
actuator cable directly to the Oval switch (XKA Kits). Connect cable to switch as shown in Fig.5.
3.
Connect a fused 12vdc or 24vdc power source as shown in Fig 5.
Power source voltage must match
the actuator voltage.
The
AUX
terminal on the Oval control
MUST
be connected to a sw12
or 24vdc source such as an ignition key switch or auxiliary panel switch. When the key switch is
turned off, the tabs automatically retract.
4.
The cut out dimension to mount the Oval switch is 2” (51mm) diameter. The switch panel is
mounted with bracket and nuts provided. Lightly tighten nuts to mounting studs (
DO NOT
OVERTIGHTEN
) (12 in-lbs./ 1.4Nm).
9
(-)
DC ground
Use 14ga. wire
Communications Port
for second station. See
Installation Manual
for details.
"OVAL " (SETR) Control Installation/Wiring Diagram
(+)12 or 24 VDC input power.
Use 14ga. wire.
12vdc = 15 or 20 amp fuse
24vdc = 10 amp fuse
This input voltage
must match the voltage rating
on the actuators being used.
Note (for S1):
"Oval" AUX terminal function:
1) Switch (S1) opens 12vdc power to initiate a
10 second tab retract and Oval control will
shut down.
2) Switch (S1) closes 12vdc power to initiate a
10 second tab retract and Oval control will
continue functioning.
3) The Aux terminal is typically connected to a
+12vdc source that is shut down after docking
to allow tabs to retract, recalibrate and prevent
damage.
(+)
(-)
AUX
BK
RD
GN
WH
GREEN
WHITE
BLACK
RED
BLACK
WHITE
BLACK
WHITE
Stbd Actuator
W4-** Interconnect
Cable
Port Actuator
BK
RD
GN
WH
W4-** (**=length) 4 conductor, 14 AWG
interconnect cable may be used or actuator
may be ordered with extended cable i.e.
A-BK-13 = 23 ft. (7m), A-BK-24 = 28 ft.
(8.5m) connecting to SETR.
Oval (SETR) Control
MUST CONNECT
(+)12 or 24 VDC
input power.
Use 16ga. wire min.
.1 to 2 amp Fuse
See Note
S1
OR
Use A-BK-13 or A-BK-24
extended cable from
actuator connecting
directly to SETR.
Port Actuator
Stbd Actuator
(+)
(-)
AUX
BK
RD
GN
WH
Oval (SETR) Control Dimensions
Port Actuator
Stbd Actuator
3.38
86mm
1.48
37.6mm
3.94
100mm
1.69
42.9mm
MUST CONNECT