![Lectrotab ELECTROMECHANICAL TRIM TAB SYSTEMS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/lectrotab/electromechanical-trim-tab-systems/electromechanical-trim-tab-systems_operation-and-installation-manual_1866731008.webp)
Flat Rocker Switch Wiring
Fig. 4
Flat Rocker Switch Wiring
1.
The SAF-SC is a flat rocker switch, and the SAB-S has an extended lever type switch handle. Both
switches are for single station applications. For dual station applications, a SAF-NSC or SAB-NS must
be used. For detailed control switch specifications, visit
www.lectrotab.com
under Products or
Technical Library/Technical Manuals or Wiring Diagrams.
2.
If the W4-** cable is used to connect the switch to actuators, route the cut cable end from the
Rocker Switch to the transom terminal strip. The push-
on terminal end of the 20’ (6.1m), 4
-
conductor, 14 AWG (2.08mm sq.) cable connects to the Rocker Switch (KA Kits), or route the longer
23’ (7m) actuator cable directly to the Rocker Switch (XKA Kits). Connect cable to switch as shown in
Fig.4.
3.
Connect a fused 12vdc or 24vdc power source as shown in Fig 4.
Power source voltage must match
the actuator voltage.
4.
The cut out dimension to mount the Rocker Switch is 2.25” (5.7cm) X 2” (5.1cm). The switch panel
is mounted with four #4 flat head screws provided.
8