Datasheet
of
the
Easy
Servo
Drive
ES2
‐
DA808
Leadshine
Technology
Co.,
Ltd
11/F,
Block
A3,
iPark,
No.1001
Xueyuan
Blvd.
Shenzhen,
China
Tel:
1
‐
949
‐
608
‐
7270
Fax:
1
‐
949
‐
608
‐
7298
Web
:
www.leadshine.com
Email:
M
ENT
There are 4 operation modes in the on-board HMI. Users can switch between these modes by pressing the “Mode”
key. The following figure illustrates the operation procedure of this on-board HMI.
M
Display Data
Edit Parameter
Select Data
ENT
Display Data
Select Parameter
Display
parameter
Edit Parameter
Confirm
M
Cancel
ENT
ENT
Select Function
Hold on 3 seconds
Reset Parameter
Clear Error Record
ENT
ENT
Auxiliary
Function
Write to
EEPROM
Start Writing
Writing Completes
ENT
M
M
M
Operation Procedure of the on-board HMI
Display Data Mode
This mode is active initially at drive’s power-up. In this mode, users can check the monitoring data as shown in the
following table.
Display Code
Name
Description
“L “
Low order digits display.
“H “
High order digits display.
7
‐
segment
Display
Left
Shift
Digits
Decrease
or
Next
Increase
or
previous
Enter,
Confirm
Mode
Switching