66
ELD2-RS70** User Manual
7.2.2 9th sort parameters specification
No.
Name
Data
type
Range
Default
value
Definition
Pr9.00
PR1 Mode
hex
0
PR path mode, determine the action according to type
property
Bit0-3
:
Motion Type ,
0 No Action
1 Position Mode
2 Speed running
3 Homing
4 Stop,
use P/V/H to express
Bit4
:
INS,
0 do no interrupt /
1 interrupt,
Use
!
to express not interrupt ,
Bit5
:
OVLP
,
0 do not overlap
1 overlap,
Use SJ to express no overlap jump, CJ to express
overlap jump,
(
right now no
)
Bit6-7
:
0 absolute
1 relative instruction
2 relative to the motor
ABS/INC/REL/
Bit8-13
:
0-15 Jump to the corresponding path
,
Use SJ0x
or CJ0x to express.
Bit14
:
JUMP
,
0 No jump
1 jump
use END to express no jump
use SJ or CJ to express jump