9. CINELITE Display
9-11
When you create a correction table, make sure that it conforms to the specifications
listed below.
Overall File Specifications
File Type
ASCII text file
Extension .CLT
End-of-Line Character
CR+LF
Number of Lines
5000 or less
Number of Characters per Line
255 or less (including CR+LF)
File Name Length
20 characters or less (excluding the extension)
Permitted File Name Characters Letters of the alphabet (A to Z; uppercase and
lowercase), numerals (0 to 9), and underscores
(_).
Comment Specifications
If you start a line with the number sign (#), the line is treated as a comment and does
not affect operations.
You can put comments anywhere.
Keyword Specifications
Be sure to put the keyword lines before the data lines and to enter a keyword without
anything preceding it at the beginning of each keyword line.
NAME:
The LV 5330 displays the eight characters that follow the separator
(colon) as the name of the correction table. After the separator, enter the
correction table name using letters of the alphabet (A to Z; uppercase and
lowercase), numbers (0 to 9), and underscores (_). You can enter up to 10
characters.
TYPE:
This is a code for identifying the file type. Enter a zero after the separator
(colon).
Data Specifications
From the start of a line, enter the input value, a separator, and then the output value, in
that order.
Input Value
Enter values from 0 to 4095 (12 bits), increasing the value by one for
each line.
A luminance level of 100 % is defined as
940 (10 bits) × 4 = 3760 (12 bits).
A luminance level of 0 % is defined as
64 (10 bits) × 4 = 256 (12 bits).
Separator
Enter a single tab code.
Output Value Enter a value from 0 to 65535 (16 bits).
2. Save the user-defined correction table to USB memory, and connect the USB memory
to the LV 5330.
Save the user-defined correction table in the USB memory’s root directory.
3. Press CINELITE.
4. Press F•6 GAMMA, and select USER-A.
In this example, a user-defined correction table is assigned to USER-A, but
user-defined correction tables can be assigned to USER-B through USER-E in the
same way.
5. Press F•7 CAL.
To clear the previous USER-A table, press F•3 TABLE CLEAR.
This setting is available when F•6 GAMMA is set to an option other than 0.45.