12. Vector Display
12-6
LINE SELECT = ON
LINE SELECT = OFF
Figure 12-7 Turning line selection on and off
12.4.2 Selecting
a
Line
To select a line, follow the procedure below. The selected line is indicated in the lower left
of the display.
Changing this setting will also change the selected line in the picture, CINELITE, video
signal waveform, and status (data dump) displays.
Procedure
VECTOR
→
F•3 LINE SELECT
→
F•D
12.4.3
Setting the Line Selection Range
To set the line selection range, follow the procedure below.
The line selection range setting is valid when the input format is set to interlaced or
segmented frame. Changing this setting will also change the picture display and video
signal waveform display line selection ranges.
Procedure
VECTOR
→
F•3 LINE SELECT
→
F•2 FIELD
Settings (the examples are the selectable ranges when the input format is 1080i/59.94)
FIELD1:
A line from field one can be selected.
(Example: 1 to 563.)
FIELD2:
A line from field 2 can be selected.
(Example: 564 to 1125.)
FRAME: