14. Status Display
14-27
• Detecting Line Number Errors
To detect line number errors, follow the procedure below. If you set this setting to ON, line
number error information appears next to LINE NUMBER in the status display.
This setting is valid when the input signal is HD-SDI.
Procedure
STATUS
→
F•5 ERROR CONFIG
→
F•3 ERROR DETECT
→
F•2 LINE ERROR
Settings
ON:
Line number errors are detected. This is the default setting.
OFF:
Line number errors are not detected.
• Detecting CRC Errors
To detect CRC errors, follow the procedure below. If you set this setting to ON, CRC error
information appears next to CRC LUMA and CRC CHROMA in the status display.
This setting is valid when the input signal is HD-SDI.
Procedure
STATUS
→
F•5 ERROR CONFIG
→
F•3 ERROR DETECT
→
F•3 CRC ERROR
Settings
ON:
CRC errors are detected. This is the default setting.
OFF:
CRC errors are not detected.
• Detecting EDH Errors
To detect EDH errors, follow the procedure below. If you set this setting to ON, EDH error
information appears next to EDH in the status display.
This setting is valid when the input signal is SD-SDI.
Procedure
STATUS
→
F•5 ERROR CONFIG
→
F•3 ERROR DETECT
→
F•4 EDH ERROR
Settings
ON:
EDH errors are detected. This is the default setting.
OFF: EDH
errors
are not detected.