User Manual
Installation
Page 11 of 22
Connecting the Battery (DC Cable)
To connect the battery, perform the following steps:
1.
Connect one DC cable to the negative terminal of the device.
2.
Connect one DC cable to the positive terminal of the device.
3.
Connect the negative terminal of the device to the negative terminal
of the battery.
4.
Secure the positive cable as close as
possible to the vehicle battery with a
suitable fuse (see table).
5.
Connect the positive terminal of the
device with the positive terminal of the
battery.
The battery is connected.
Connecting the Remote Switch
To connect an external remote switch, perform the following steps:
1.
Connect an external on/off switch to the positive terminal of the
battery (DC voltage min. 10 V, max. 30 V).
Notice: Secure the on/off switch with max. 1 A (with 0.75 mm
2
).
2.
Connect the on/off switch to the remote pin of the device.
The remote switch is connected.
Connecting Consumers
To connect consumers, perform the following steps:
1.
Insert the plug of the consumer into the Neutrik input (grey) of the
device.
A Neutrik plug is included. You will find information on how to
install the Neutrik plug on p. 18.
2.
Be sure that sufficient personal and line safety devices are available
according to your application.
The consumer is connected.
Model
Fuse
1012
125 A, slow-blow
1024
80 A, slow-blow
1312
175 A, slow-blow
1512
175 A, slow-blow
1524
100 A, slow-blow
2012
250 A, slow-blow
2324
150 A, slow-blow