Mounting
To mount the device, perform the following steps:
NOTICE
Choose a cool, dry and well-ventilated mounting site. The device must
be protected from dust and moisture.
Do not mount the device directly next to or above batteries.
Mount the device on a flat surface.
Optimum cooling is achieved with vertical mounting.
1.
Fasten the device with screws to the 4 lateral holes (5 mm Ø).
The device is mounted.
8
Installation
Determining the Cable Cross-section of the Input Lead (DC)
The following table shows the required cable cross-sections in relation to
the respective cable length. Select the cross-sections so that the voltage
drop to the G3 Combi is no more than 250 mV.
To avoid voltage dips, select a higher cable cross-section for
consumers with high starting currents (e.g. motors, compressors).
Cable
Cross-
section
Device model
mm
2
1012-
50
1312-
80
1512-
80
2012-
100
1024-
30
1524-
40
2324-
50
15
-
-
-
-
1.5 m
-
-
25
1.5 m
-
-
-
2.5 m
1.5 m
-
35
2 m
1.5 m
1.5 m
-
3 m
2.5 m
1.5 m
50
3 m
2 m
2 m
1.5 m
-
3 m
2 m
70
-
3 m
2.5 m
2 m
-
-
3 m