User Manual
Maintenance
Page 18 of 22
All LEDs
Description
Flickering
Remote and mains switch on the device
at the same time
..
..
….......................
NTC error (internal temperature sensor)
..
..
……...........
Overvoltage in the internal high-voltage
DC connection
..
..
……..
Defect in half of the bridge circuit
..
..
Defect in the entire bridge circuit
12
Maintenance
Maintain the device at regular intervals.
Ensure that the cables on the battery and the G3 Combi are
secure.
To ensure the air supply, clean the ventilation grille of the device.
13
Mount Neutrik Plug
Use the following plug to connect the consumers:
AC output plug, Neutrik NAC3FCB model – grey
AC input plug, Neutrik NAC3FCA model – blue
Connections
Cable preparation
Sleeve
Insert
Clamp sleeve
Screw connection