Page 45
For HELP, call In-Touch at 866.461.3123
Draining and Refilling
Figure 30 - Drain Operation
1) Turn off the GFCI breaker.
2) Remove spa cover and allow water to cool down.
3) Select a safe, suitable drainage area capable of safely assimilating
300 plus gallons of water that may contain unsanitary contaminants
and chemical residue that could cause harm to plants or grass.
4) Locate drain valve at front of the spa (see page 16). Hold the rear
body to prevent it from turning, then loosen and remove the front
cap.
5) Attach a garden hose to the exposed threads and route the hose
downhill to your drainage area.
6) Twist the drain fitting 1/3 turn counterclockwise to unlock the drain
valve and pull it outward to open completely. The water will drain by
gravitational flow.
7) After the spa drains, perform steps 3-5 in reverse order to close the
drain prior to refilling spa.
8) Attach the garden hose to a thoroughly-flushed AquaClara pre-filter
(not included, rinsed of all residual sediment) and refill your spa
through the filtration canister.
9) After refilling, turn on the GFCI breaker to the spa.
If the pump runs but no water flows, see page 39 to see how to bleed air
from the system.