LAWSON ENGINEERS LTD Ref : PJ1682
Issue Date : 06.06.2006
- 44 -
Winch 1 Proportional Valve Driver Unit
MW 12
Out 1 +
CQ 2.0 +
7
SW1673X-0008/20/1
+/- 10V dc
Out 1 0V
CQ 2.0 −
8
SW1673X-0008/20/1
CO / 24 V1
1
SW1673X-0008/20/1
C1 / 24 V1
2
SW1673X-0008/20/1
O V 1
3
SW1673X-0008/20/1
11
100
C14 1 Red
1
SW1673X-0008/20/1 SW1673X-0007/01/6
12
101
C14 2 Blue
2
SW1673X-0008/20/1 SW1673X-0007/01/6
9
102
C18 1 Red
1
SW1673X-0008/20/2 SW1673X-0007/01/6
10
103
C18 2 Blue
2
SW1673X-00008/20/2 SW1673X-0007/01/6
Winch 2 Proportional Valve Driver Unit
MW 13
Out 2 +
CQ 2.1 +
7
SW1673X-0008/20/3
+/- 10V dc
Out 2 0V
CQ 2.1 −
8
SW1673X-0008/20/3
CO / 24 V1
1
SW1673X-0008/20/3
C1 / 24 V1
2
SW1673X-0008/20/3
O V 1
3
SW1673X-0008/20/3
11
104
C13 1 Red
1
SW1673X-0008/20/3 SW1673X-0007/01/6
12
105
C13 2 Blue
2
SW1673X-0008/20/3 SW1673X-0007/01/6
9
106
C17 1 Red
1
SW1673X-0008/20/4 SW1673X-0007/01/6
10
107
C17 2 Blue
2
SW1673X-0008/20/4 SW1673X-0007/01/6
Winch 3 Proportional Driver Module
MW 14
Out 1 +
CQ 3.0 +
7
SW1673X-0008/20/6
+/- 10V dc
Out 1 0V
CQ 3.0 −
8
SW1673X-0008/20/6
CO / 24 V1
1
SW1673X-0008/20/6
C1 / 24 V1
2
SW1673X-0008/20/6
O V 1
3
SW1673X-0008/20/6
11
108
C12 1 Red
1
SW1673X-0008/20/6 SW1673X-0007/01/6
12
109
C12 2 Blue
2
SW1673X-0008/20/6 SW1673X-0007/01/6
9
110
C16 1 Red
1
SW1673X-0008/20/6 SW1673X-0007/01/6
10
111
C16 2 Blue
2
SW1673X-0008/20/6 SW1673X-0007/01/6
Spare
MW 15
Out 2 +
CQ 3.1 +
SW1673X-0008/20/8
+/- 10V dc
Out 2 0V
CQ 3.1 −
SW1673X-0008/20/8
Drawing No./
Sheet/Column
PLC
Connection
Cable/ Wire
No.
Drawing No./
Sheet/Column
Signal
type
Cable/Wire
No.
Destination
Drawiing
No./Sheet/column
Description
PLC
Assignment
Signal
type
Winch Remote Unit - Module Slot 5, Card Type: 2 Channel Analogue Output Module, Card Part No.: TWD AVO 2 HT
Winch Remote Unit - Module Slot 4, Card Type: 2 Channel Analogue Output Module, Card Part No.: TWD AVO 2HT
Description
PLC
Assignment
PLC
Connection
Cable/ Wire
No.
Cable/Wire
No.
Drawing No./
Sheet/Column
Drawing No./
Sheet/Column
Destination
Drawiing
No./Sheet/column