background image

24

A STEELFORT PRODUCT 

WARRANTY

3-YEAR DOMESTIC CONDITIONAL WARRANTY 

UP TO 90 DAYS FOR COMMERCIAL USE. 

LawnMaster Dealer extended warranty period for 

items that are:

• 

Registered at the time of sale.

• 

Serviced by an Authorised LawnMaster Service 

Dealer in accordance with the service schedule 

using Genuine parts and oils (proof required).

• 

Meeting all other warranty requirements.

LAWNMASTER LIMITED WARRANTY

The warranty applies to all new LawnMaster products 

that are identified by their unit serial number.

In order to be eligible for the LawnMaster limited 

warranty, you must have, maintenance performed 

according to the schedule contained in the relevant 

owner’s manual that is supplied with the product, and 

ongoing maintenance performed by an authorised 

LawnMaster dealer.

Steelfort will recognise your statutory rights under 

the Consumers Guarantee Act 1993. To ensure 

the safe operation of this product, we strongly 

recommend that you only use an authorised 

LawnMaster dealer for all maintenance and servicing 

requirements. Authorised LawnMaster Dealers have 

access to special tools, training, and genuine parts 

that are required to maintain your LawnMaster 

product for peak operating conditions.

The purchaser must keep an accurate record of all 

service and maintenance. This may be requested 

when assessing any future warranty claims.

To qualify for the LawnMaster extended Warranty, 

a warranty registration must be completed online 

through the Steelfort website (www.steelfort.co.nz) 

within ten (10) days following the date of purchase.

Proof of purchase documentation are required and 

must include the engine serial number and frame 

serial number as appropriate for all warranty claims. 

Authorised LawnMaster dealers are able to repair 

and or replace parts that are defective within the 

limits of this warranty at no expense to the owner, 

and this includes the cost for replacement parts and 

or labour. Consumable items such as, but not limited 

to, oils, coolants, filters and spark plugs maybe an 

additional charge at the expense of the owner. All 

defective parts will be replaced and become the 

property of Steelfort. 

Transportation costs related to freight and or 

delivery of replacement parts, and or whole goods 

maybe an additional charge at the expense of the 

owner. 

WARRANTY EXCLUSIONS

• 

Any damage which results from neglect of 

periodic maintenance specified by Steelfort.

• 

Any damage resulting from repair or 

maintenance by methods other than specified 

by Steelfort.

• 

Any product which has participated in a 

competition racing or rally event. 

• 

Any damage which results from misuse and 

or use beyond the limitations of the intended 

purpose specified by Steelfort, such as 

overloading, and or under abnormal conditions. 

• 

Any damage resulting from the use of non-

genuine parts, lubricant or fluid not approved 

by Steelfort.

• 

Any damage resulting from modification or 

installation in other products in a way that is 

not approved by Steelfort that has an influence 

on the function and/or performance of the 

products.

• 

Any damage that results from operating under 

conditions that are not specified in the Owner’s 

Manual either intentionally or by error.

• 

Fading of painted surfaces, deterioration of 

plated surfaces, deterioration of rubber and 

plastics including, rusting due to the passage 

of time.

 

Содержание LGBQH6200

Страница 1: ...SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT SILENTINVERTER GENERATOR PROUDLY NZ OWNED A STEELFORT PRODUCT LGBQH6200 E...

Страница 2: ...ounding LGP Cylinder Check Inspection Of Connection With LGP STARTING THE GENERATOR 11 Recoil Start Electric Start LGP CONNECTING TO THE ELECTRICAL DEVICES 14 Loading Capacity Wattage Reference Chart...

Страница 3: ...ial use may void warranty These generators are designed for full time operation No personal modifications should be made to any part of the unit DANGER TOXIC FUMES The exhaust of the engine contains c...

Страница 4: ...untrained people to operate the unit DO NOT leave the generator unattended when it is in operation Always turn off the generator prior to leaving the area ELECTRIC SHOCK The generator produces powerfu...

Страница 5: ...nel when installing the right maintenance panel back into place USAGE OF HANDLE CAUTION Make sure the generator is placed on a level ground before using the handle After the handle button is pressed t...

Страница 6: ...rt Handle 11 Combination Switch Start If Equipped Run Shut Off And Flameout 12 Right Maintenance Panel 13 Rear Lift Handle 14 Muffler Screen 15 Muffler 1 Overcurrent Protector 2 AC Output 3 Ground Ter...

Страница 7: ...gine automatically and oil alarming lamp will blink when recoil starter is pulled The engine will not run until the oil has been filled to the proper level Note If engine stalls or fails to start turn...

Страница 8: ...not present when generator has not been used for long periods Note If you do not plan to use the generator in the near future please use this function or drain the fuel inside the carburettor using th...

Страница 9: ...at altitudes above 5 000 feet 1 500 meters CAUTION Even with carburetor modification generator horsepower will decrease by 3 5 for every 1 000 feet 300 meters increase in altitude The effect of altitu...

Страница 10: ...eposits from forming in essential fuel system components such as the carburetor fuel filter fuel hose or tank during longterm storage Also experience indicates that alcohol blended fuels gasohol ethan...

Страница 11: ...leaks If bubbles appear and become larger it indicates that any connector is not installed in place or is damaged resulting in leakage Please close the fuel cylinder valve and turn off the generator i...

Страница 12: ...l be started and the start button will be reset automatically WARNING When the generator cannot be started through electric start due to low battery power which is caused by generator idling for a lon...

Страница 13: ...he generator after using other batteries without authorization STARTING THE GENERATOR WITH LGP IF EQUIPPED 1 Perform pre use inspection items and remove all loads 2 Connection steps of relief valve as...

Страница 14: ...e risk of electrical shock DO NOT use electrical cords that are worn frayed bare or otherwise damaged DO NOT touch bare wires or receptacles DO NOT handle generator or electrical cords while standing...

Страница 15: ...enerator is idle for a long time If the generator needs to be idle for a long time please turn the fuel cock to Shut off position Turn the combination switch to Flameout position until the fuel in the...

Страница 16: ...DULE Before servicing the generator stop the gen erator disconnect all electric devices and battery if equipped and allow the generator to cool down Follow the service intervals indicated in the chart...

Страница 17: ...n the average temperature in your area is within the indicated range OIL MUST BE PLACED IN ENGINE BEFORE STARTING Ambient temperature Oil capacity rated See Parameters 3 2 ADDING OIL WARNING The engin...

Страница 18: ...nt 3 Wash in liquid detergent and warm water 4 Squeeze thoroughly dry in a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a clean absorbent cloth to remove all excess oil 7 Place the filter i...

Страница 19: ...mpletely before servicing the spark arrester 2 Remove the muffler blind window first 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wir...

Страница 20: ...ecoil starter slightly to distribute the oil and lubricate the cylinder And then attach the spark plug 7 Store the unit in a clean dry area out of direct sunlight 8 Disconnect the battery TRANSPORTATI...

Страница 21: ...21 A STEELFORT PRODUCT TROUBLE SHOOTING...

Страница 22: ...PRODUCT SPECIFICATIONS WIRING DIAGRAMS 1 SPECIFICATION PARAMETER TABLE Note The generating set with different specification and configurations may have different parameters and may change at any time...

Страница 23: ...23 A STEELFORT PRODUCT 2 WIRING DIAGRAMS BQH6200E ELECTRIC START Note This circuit diagram is for reference only due to the generator set condition difference...

Страница 24: ...f purchase documentation are required and must include the engine serial number and frame serial number as appropriate for all warranty claims Authorised LawnMaster dealers are able to repair and or r...

Страница 25: ...s that are incurred in the warranty claim for additional expenses such as towing communications accommodation and meals that are incurred due to the breakdown of the product at a remote location are n...

Страница 26: ...0 Rangitikei Street Private Bag 11045 Palmerston North 4412 New Zealand 06 350 1350 Steelfort Auckland 880 Great South Road Penrose Auckland 1061 New Zealand 09 573 1324 lawnmasternz FIND US www lawnm...

Отзывы: