background image

10

A STEELFORT PRODUCT 

Reinstall and fully tighten the dipstick. 

Refer to add oil instruction in MAINTENANCE section 

for more information. 

Oil level: 0.85 L 

Recommended grade of engine oil: SAE10W-30 

WARNING 

• 

Oil is a major factor affecting performance and 

service life.

• 

We recommend using LawnMaster 4-Stroke 

10W30 Oil (PP01020005). You can find more 

information about this in the MAINTENANCE 

section of this manual.

• 

OIL MUST BE PLACED IN ENGINE BEFORE 

STARTING.

 This engine is not filled with oil at 

the factory. Any attempt to crank or start the 

engine before it has been properly filled with 

the recommended type and amount of oil may 

result in engine damage and void your warranty.

CAUTION 

Operate generator only on level surfaces. The engine 

is equipped with a low oil sensors (if applicable) that 

will automatically stop the engine when the oil level 

falls below safe threshold. To avoid the inconvenient  

unexpected shutdowns, fill to the upper limit and 

check oil levels regularly.

4. ENGINE FUEL 

• 

With the engine stopped, check the fuel level 

gauge. Refill the fuel tank if necessary. 

• 

Use clean, fresh, regular unleaded petrol. 

• 

DO NOT mix oil with petrol. 

• 

Always wipe up any spilled fuel. 

• 

Be sure not to fill above the upper limit mark

• 

Always allow room for fuel expansion.

• 

DO NOT use engine and or carburetor cleaning 

products in the fuel tank as this could result in 

permanent damage. 

• 

It is important to prevent gum deposits from 

forming in essential fuel system components, 

such as the carburetor, fuel filter, fuel hose or 

tank during longterm storage. Also, experience 

indicates that alcohol-blended fuels (gasohol, 

ethanol or methanol) can attract moisture, 

which could lead to separation and formation of 

acids during longterm storage. 

• 

Acidic fuels can damage the fuel system while 

in storage. Be sure to review the instructions in 

the “Storage” section. 

• 

Petrol/Alcohol Blends: up to 10% alcohol, 90% 

unleaded petrol by volume is approved as a fuel. 

Other forms of petrol/alcohol blends are not 

approved. 

• 

Damage and faults caused by old, stale or 

contaminated fuel may void warranty.

DANGER 

• 

Do not fill the fuel tank above the upper limit. 

Over filling will result in engine damage and 

may void warranty.

• 

Petrol is highly flammable and extremely 

explosive. Keep flammable items away while 

handling petrol as this could result in a fire.

• 

Fill fuel tank outdoors and well-ventilated areas 

with the generator stopped. 

• 

Always wipe off spilled fuel and wait until the 

fuel has dried before starting the generator.

CAUTION

• 

To minimise gum deposits in your fuel system 

and to insure easy starting, do not use petrol 

that is left over from the previous seasons.

• 

Pressure can build up in the fuel tank. Allow 

the generator to cool for at least two minutes 

before removing fuel cap. Loosen the fuel cap 

slowly to relieve any pressure in the tank. 

5. OPERATION PLACE

• 

Fill to the upper limit of the dipstick with the 

recommended oil if the oil level is too low.

Before starting the generator, disconnect the 

electrical device from the generator and turn off

Содержание LGBQH6200

Страница 1: ...SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT SILENTINVERTER GENERATOR PROUDLY NZ OWNED A STEELFORT PRODUCT LGBQH6200 E...

Страница 2: ...ounding LGP Cylinder Check Inspection Of Connection With LGP STARTING THE GENERATOR 11 Recoil Start Electric Start LGP CONNECTING TO THE ELECTRICAL DEVICES 14 Loading Capacity Wattage Reference Chart...

Страница 3: ...ial use may void warranty These generators are designed for full time operation No personal modifications should be made to any part of the unit DANGER TOXIC FUMES The exhaust of the engine contains c...

Страница 4: ...untrained people to operate the unit DO NOT leave the generator unattended when it is in operation Always turn off the generator prior to leaving the area ELECTRIC SHOCK The generator produces powerfu...

Страница 5: ...nel when installing the right maintenance panel back into place USAGE OF HANDLE CAUTION Make sure the generator is placed on a level ground before using the handle After the handle button is pressed t...

Страница 6: ...rt Handle 11 Combination Switch Start If Equipped Run Shut Off And Flameout 12 Right Maintenance Panel 13 Rear Lift Handle 14 Muffler Screen 15 Muffler 1 Overcurrent Protector 2 AC Output 3 Ground Ter...

Страница 7: ...gine automatically and oil alarming lamp will blink when recoil starter is pulled The engine will not run until the oil has been filled to the proper level Note If engine stalls or fails to start turn...

Страница 8: ...not present when generator has not been used for long periods Note If you do not plan to use the generator in the near future please use this function or drain the fuel inside the carburettor using th...

Страница 9: ...at altitudes above 5 000 feet 1 500 meters CAUTION Even with carburetor modification generator horsepower will decrease by 3 5 for every 1 000 feet 300 meters increase in altitude The effect of altitu...

Страница 10: ...eposits from forming in essential fuel system components such as the carburetor fuel filter fuel hose or tank during longterm storage Also experience indicates that alcohol blended fuels gasohol ethan...

Страница 11: ...leaks If bubbles appear and become larger it indicates that any connector is not installed in place or is damaged resulting in leakage Please close the fuel cylinder valve and turn off the generator i...

Страница 12: ...l be started and the start button will be reset automatically WARNING When the generator cannot be started through electric start due to low battery power which is caused by generator idling for a lon...

Страница 13: ...he generator after using other batteries without authorization STARTING THE GENERATOR WITH LGP IF EQUIPPED 1 Perform pre use inspection items and remove all loads 2 Connection steps of relief valve as...

Страница 14: ...e risk of electrical shock DO NOT use electrical cords that are worn frayed bare or otherwise damaged DO NOT touch bare wires or receptacles DO NOT handle generator or electrical cords while standing...

Страница 15: ...enerator is idle for a long time If the generator needs to be idle for a long time please turn the fuel cock to Shut off position Turn the combination switch to Flameout position until the fuel in the...

Страница 16: ...DULE Before servicing the generator stop the gen erator disconnect all electric devices and battery if equipped and allow the generator to cool down Follow the service intervals indicated in the chart...

Страница 17: ...n the average temperature in your area is within the indicated range OIL MUST BE PLACED IN ENGINE BEFORE STARTING Ambient temperature Oil capacity rated See Parameters 3 2 ADDING OIL WARNING The engin...

Страница 18: ...nt 3 Wash in liquid detergent and warm water 4 Squeeze thoroughly dry in a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a clean absorbent cloth to remove all excess oil 7 Place the filter i...

Страница 19: ...mpletely before servicing the spark arrester 2 Remove the muffler blind window first 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wir...

Страница 20: ...ecoil starter slightly to distribute the oil and lubricate the cylinder And then attach the spark plug 7 Store the unit in a clean dry area out of direct sunlight 8 Disconnect the battery TRANSPORTATI...

Страница 21: ...21 A STEELFORT PRODUCT TROUBLE SHOOTING...

Страница 22: ...PRODUCT SPECIFICATIONS WIRING DIAGRAMS 1 SPECIFICATION PARAMETER TABLE Note The generating set with different specification and configurations may have different parameters and may change at any time...

Страница 23: ...23 A STEELFORT PRODUCT 2 WIRING DIAGRAMS BQH6200E ELECTRIC START Note This circuit diagram is for reference only due to the generator set condition difference...

Страница 24: ...f purchase documentation are required and must include the engine serial number and frame serial number as appropriate for all warranty claims Authorised LawnMaster dealers are able to repair and or r...

Страница 25: ...s that are incurred in the warranty claim for additional expenses such as towing communications accommodation and meals that are incurred due to the breakdown of the product at a remote location are n...

Страница 26: ...0 Rangitikei Street Private Bag 11045 Palmerston North 4412 New Zealand 06 350 1350 Steelfort Auckland 880 Great South Road Penrose Auckland 1061 New Zealand 09 573 1324 lawnmasternz FIND US www lawnm...

Отзывы: