3. Select according to the actual configuration
of the user
RECOIL START
To start the generator, hold the handle of the
recoil starter and pull it slowly until there is
resistance and then quickly pull the handle to
start the generator.
WARNING:
Please check the condition of the starter rope
before use. If the rope is seriously worn, please
replace it at the authorized local dealer in time.
WARNING - RECOIL
When the recoil starter retracts quickly after
start-up, the hand and arm will be pulled toward
the engine faster.
Unpreparedness may result in accidental injury.
CAUTION
During start-up, the choke may be affected by
temperature or other factors and may require
different openings.
ELECTRIC START {IF CONFIGURED)
Press and hold the start button for 0.3-5 s
and then release it, and the generator will
be started, and the start button will be reset
automatically.
WARNING
When the generator cannot be started through
electric start due to low battery power, which
is caused by generator idling for a long time or
in improper use, please manually control the
damper and start the generator according to
the steps for recoil start, The generator will
automatically charge the battery after normal
operation.
PUSH BUTTON (IF CONFIGURED)
Push the button once to start the generator
CAUTION
After the generator is used for a period of time,
if the push speed of the motor decreases, it
means that the battery needs to be replaced.
Before shutting down the generator, ensure
that the combination switch in “Flameout”
position, to prevent battery power loss, which
may affect the next start.
If the generator still fails to be started or is shut
down after three attempts, find the cause of
the fault and eliminate it.
The engine oil alarm prevents the generator
from being started when the oil level in the
crankcase is below the lower limit.