background image

14

A STEELFORT PRODUCT 

Push by push button

Suitable for recoil start and electric start

After the generator is started, turn the combination 

switch to “RUN” position. After the above operation, 

the generator can be loaded.

CONNECT TO ELECTRICAL 

DEVICES

Inspect power cord for damage before using. A 

hazard is electrical shocks from crushing, cutting or 

heat damage.

1. 

Confirm that the generator is grounded. If 

the electric device requires grounding, the 

generator must be grounded.

2. 

Ensure that all electrical devices are turned off.

3. 

After the generator is started, let it run for a 

few minutes to allow it to warm up to a steady 

state.

4. 

Confirm the connection and then turn on the 

electric device you expected.

5. 

Before stopping the generator, please turn off 

the electrical device or disconnect the output.

6. 

If the generator provides power to more than 

one electrical devices, start each electrical 

device according to the size of the load, from 

small to large.

DANGER

If connected devices overheat, turn them off and 

disconnect them from generating set.

ELECTRICAL SHOCK

 

• 

To reduce the risk of electrical shock, DO NOT 

use electrical cords that are worn, frayed, bare 

or otherwise damaged. 

• 

DO NOT touch bare wires or receptacles. 

• 

DO NOT handle generator or electrical cords 

while standing in water, while barefoot, or while 

hands or feet are wet.

LOADING CAPACITY 

You must make sure your generator can supply 

enough rated (running) and surge (starting) watts for 

the electrical devices you plan to power at the same 

time. Follow these simple steps to calculate the 

running and starting watts that are necessary for 

your purposes.

WARNING

• 

DO NOT overload the generator. 

• 

Exceeding the generator’s capacity can   

damage the generator and/or electrical devices  

connected to it. Faults and damaged caused by  

overloading may void warranty. 

1. 

Select the electrical devices you will power at 

the same time.

2. 

The amount of power you need to run all the 

devices is the total rated (running) watts of 

these items.

3. 

Identify how many surge (starting) watts you 

will need. Surge wattage is the short burst of 

power needed to start electric power tools and  

or appliances. Because not all motors start at 

the same time, total surge watts can    

be estimated by adding only the electrical  

device(s) with the highest additional surge 

watts to the total rated watts from step 2. 

WATTAGE REFERENCE CHART

Содержание LGBQH6200

Страница 1: ...SAFETY AND OPERATING MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT SILENTINVERTER GENERATOR PROUDLY NZ OWNED A STEELFORT PRODUCT LGBQH6200 E...

Страница 2: ...ounding LGP Cylinder Check Inspection Of Connection With LGP STARTING THE GENERATOR 11 Recoil Start Electric Start LGP CONNECTING TO THE ELECTRICAL DEVICES 14 Loading Capacity Wattage Reference Chart...

Страница 3: ...ial use may void warranty These generators are designed for full time operation No personal modifications should be made to any part of the unit DANGER TOXIC FUMES The exhaust of the engine contains c...

Страница 4: ...untrained people to operate the unit DO NOT leave the generator unattended when it is in operation Always turn off the generator prior to leaving the area ELECTRIC SHOCK The generator produces powerfu...

Страница 5: ...nel when installing the right maintenance panel back into place USAGE OF HANDLE CAUTION Make sure the generator is placed on a level ground before using the handle After the handle button is pressed t...

Страница 6: ...rt Handle 11 Combination Switch Start If Equipped Run Shut Off And Flameout 12 Right Maintenance Panel 13 Rear Lift Handle 14 Muffler Screen 15 Muffler 1 Overcurrent Protector 2 AC Output 3 Ground Ter...

Страница 7: ...gine automatically and oil alarming lamp will blink when recoil starter is pulled The engine will not run until the oil has been filled to the proper level Note If engine stalls or fails to start turn...

Страница 8: ...not present when generator has not been used for long periods Note If you do not plan to use the generator in the near future please use this function or drain the fuel inside the carburettor using th...

Страница 9: ...at altitudes above 5 000 feet 1 500 meters CAUTION Even with carburetor modification generator horsepower will decrease by 3 5 for every 1 000 feet 300 meters increase in altitude The effect of altitu...

Страница 10: ...eposits from forming in essential fuel system components such as the carburetor fuel filter fuel hose or tank during longterm storage Also experience indicates that alcohol blended fuels gasohol ethan...

Страница 11: ...leaks If bubbles appear and become larger it indicates that any connector is not installed in place or is damaged resulting in leakage Please close the fuel cylinder valve and turn off the generator i...

Страница 12: ...l be started and the start button will be reset automatically WARNING When the generator cannot be started through electric start due to low battery power which is caused by generator idling for a lon...

Страница 13: ...he generator after using other batteries without authorization STARTING THE GENERATOR WITH LGP IF EQUIPPED 1 Perform pre use inspection items and remove all loads 2 Connection steps of relief valve as...

Страница 14: ...e risk of electrical shock DO NOT use electrical cords that are worn frayed bare or otherwise damaged DO NOT touch bare wires or receptacles DO NOT handle generator or electrical cords while standing...

Страница 15: ...enerator is idle for a long time If the generator needs to be idle for a long time please turn the fuel cock to Shut off position Turn the combination switch to Flameout position until the fuel in the...

Страница 16: ...DULE Before servicing the generator stop the gen erator disconnect all electric devices and battery if equipped and allow the generator to cool down Follow the service intervals indicated in the chart...

Страница 17: ...n the average temperature in your area is within the indicated range OIL MUST BE PLACED IN ENGINE BEFORE STARTING Ambient temperature Oil capacity rated See Parameters 3 2 ADDING OIL WARNING The engin...

Страница 18: ...nt 3 Wash in liquid detergent and warm water 4 Squeeze thoroughly dry in a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a clean absorbent cloth to remove all excess oil 7 Place the filter i...

Страница 19: ...mpletely before servicing the spark arrester 2 Remove the muffler blind window first 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wir...

Страница 20: ...ecoil starter slightly to distribute the oil and lubricate the cylinder And then attach the spark plug 7 Store the unit in a clean dry area out of direct sunlight 8 Disconnect the battery TRANSPORTATI...

Страница 21: ...21 A STEELFORT PRODUCT TROUBLE SHOOTING...

Страница 22: ...PRODUCT SPECIFICATIONS WIRING DIAGRAMS 1 SPECIFICATION PARAMETER TABLE Note The generating set with different specification and configurations may have different parameters and may change at any time...

Страница 23: ...23 A STEELFORT PRODUCT 2 WIRING DIAGRAMS BQH6200E ELECTRIC START Note This circuit diagram is for reference only due to the generator set condition difference...

Страница 24: ...f purchase documentation are required and must include the engine serial number and frame serial number as appropriate for all warranty claims Authorised LawnMaster dealers are able to repair and or r...

Страница 25: ...s that are incurred in the warranty claim for additional expenses such as towing communications accommodation and meals that are incurred due to the breakdown of the product at a remote location are n...

Страница 26: ...0 Rangitikei Street Private Bag 11045 Palmerston North 4412 New Zealand 06 350 1350 Steelfort Auckland 880 Great South Road Penrose Auckland 1061 New Zealand 09 573 1324 lawnmasternz FIND US www lawnm...

Отзывы: