Figure 9.6.7
Figure 9.6.8
Figure 9.6.9
Figure 9.6.10
When
the
tool
holder
is
dismounted,
you
can
change
the
sealers
(V
‐
Ring
and
Felt
‐
Ring).
Take
out
Felt
‐
Ring,
Adaptor
and
V
‐
Ring.
Before
mounting
check
on
which
side
the
adaptor
is
fitting,
remember
the
correct
side.
Mount
the
V
‐
Ring
with
the
smallest
lip
of
the
V
to
inside
(Fig.9.6.7)
just
push
the
V
‐
ring
so
the
top
is
on
the
same
level
as
the
pulley
top
(Fig.9.6.8).
Then
take
the
adaptor
in
the
correct
way
and
push
the
V
‐
Ring
down
with
the
adaptor
(Fig.9.6.9).
The
lowest
lip
of
the
V
‐
Ring
should
only
barely
touch
its
gliding
surface;
also
never
push
the
V
‐
Ring
down
with
fingers.
Mount
now
the
Felt
‐
ring
on
top
(Fig.9.6.10).
Close
the
sealers
with
the
cap
(Fig.9.6.11).
9.7
TENSIONING
AND
REPLACING
THE
PLANETARY
BELT
If
the
belt
slips
or
is
broken,
separate
the
carriage
from
main
head
(Fig.
9.7.1).
Take
off
handles,
fork,
top
frame,
and
weight
holders
so
you
can
push
up
the
top
cover
(Fig.
9.7.2).
9.8
TENSIONING
USED
PLANETARY
BELT
Noticing
speed
lost
in
planetary
movement
it
is
possible
to
tension
the
belt
for
planetary
movement
as
described
in
9.9:
Mounting
and
tensioning
a
new
planetary
belt.
Figure 9.8.1
Figure 9.8.2
Figure 9.6.11
Figure 9.7.1
Figure 9.7.2