![LAVAMAC LDR-900-S Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/lavamac/ldr-900-s/ldr-900-s_installation-operation-and-maintenance_4027764081.webp)
Maintenance
Part No. 70476501ENR7
81
4. Check steam connections for looseness and leakage.
5. Remove all front panels and vacuum, including coin drop
mechanisms.
6. Check cylinder and front panel seals.
7. Inspect cabinet and inner panels for any damage, replace or
repair as needed.
8. Clean burner tubes and orifice area of any lint buildup.
Annually
1. Remove burner tubes.
2. Clean using water and a brush.
Fire Suppression System (Optional
Equipment) Maintenance Test
NOTE: Fire suppression system only available on gas
and steam models.
To ensure proper operation, the fire suppression system must be
tested every three months. If the system test does not perform as
indicated:
1. Discontinue use of the tumble dryer.
2. Refer to Troubleshooting Manual or contact a qualified
service person.
3. Restore the fire suppression system to proper working order
before using tumble dryer.
Create a maintenance record with a check box for pass, the date
and a signature. Store this record in an area where it will not be
damaged, but is easily accessible to person performing tests.
NOTE: Failure to maintain the fire suppression system
will void the tumble dryer warranty.
NOTE: The auxiliary output is activated during the
fire suppression system maintenance test sequence.
Consider this fact prior to testing the system every
three months. (Example – If the external system
uses the auxiliary output to call the fire department,
inform the fire department before and after the fire
suppression system maintenance test.)
CAUTION
Clean up any water spilled during testing to avoid
personal injury.
W487
1 Opening for Auxiliary Alarm Cable
2 Test Button
3 Light
4 Reset Button
Figure 47
To perform the fire suppression system maintenance test:
1. If the auxiliary alarm output is connected to a separate alarm
system, disconnect prior to performing the fire suppression
system maintenance test.
2. Remove any lint from the lint compartment.
3. Ensure temperature sensors are free of lint.
4. Place a load of dry towels in the tumble dryer. Refer to
Table 16 for proper load size. Ensure the cylinder baffles
are to the left and right of the spray manifold located at the
center top of the cylinder.
5. Unlock the fire suppression system control box.
6. Press and hold the test button, verify the light is on, this
should take approximately five seconds. Refer to Figure 47
. After a one-second pause water should begin to spray into
the cylinder.
7. After 15 seconds of water spray, press and hold the reset
button until water spray is off and light is off. This should
take approximately one second. Refer to Figure 47 and
Figure 48 .
8. Immediately remove and weigh the load. Refer to Table 16
for acceptable weight range. If less than minimum pounds
indicated in Table 16 , the fire suppression system has failed
the maintenance test. Refer to the Troubleshooting Manual.
IMPORTANT: If the fire suppression system failed
the maintenance test, DO NOT operate the tumble
dryer.