Installation
36
Part No. 70476501ENR7
1 Gas Shut-Off Valve (Ahead of pressure tap) (Not
Supplied)
2 Pressure Tap
3 Gas Shut-Off Valve (Shown in closed position) (Not
Supplied)
4 Specified Local Inlet Pressure
Figure 7
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumble dryers were
ordered, but unregulated tumble dryers were needed.
1. Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 7 .
2. Follow instructions in Conversion Kit.
Models through 3/10/13
Part No. M400763 (two
kits required)
Models starting 3/11/13
Part No. 44240401P
NOTE: These kits do not contain any burner
orifices.
3. Replace burner orifice(s) as per Table 1 .
4. If applicable, peel off the appropriate conversion sticker
(included with machine) and apply it to the serial plate over
the “ADJUSTED FOR ______ GAS: ______” information.
5. Commission tumble dryer for use.
How to Change Burner Orifice Size
1. Disconnect electrical power from tumble dryer. Close gas
shut-off valve to tumble dryer. Refer to Figure 7 .
Содержание LDR-900-S
Страница 2: ......