Installation
42
INSTALLATION, MAINTENANCE AND USER' MANUAL
549263_D_PUB_DATE_7_JUL_2014.DOC
DRAIN HOSE BEND
Figure 24
Drain pump
Machines 7-8 kg / 15-18 lb
Connect a flexible hose of a 24 mm / 0.94“ diameter to a drain
pipe in manner providing sufficient siphon effect (the hose bend
must not be located lower than the water level). In order to achieve
good draining, the hose must not bend at a sharp angle.
Venting
WARNING
VAPOURS ESCAPE FROM THE MACHINE THROUGH THE AIR VENT OPENING!
SEE FIGURES 1, 2, POSITION 22. DO NOT COVER!
Steam connection
WARNING
INSTALL A STEAM SUPPLY DISCONNECTING DEVICE IN THE VICINITY OF EACH WASHER.
DISCONNECT THE STEAM SUPPLY ALWAYS BEFORE ANY SERVICE OR INTERVENTION, GIVING
SUFFICIENT TIME TO COOL DOWN THE PARTS TO AVOID INJUIRES.
WARNING
IT IS NECESSARY TO INSERT A FILTER WITH PERMEABILITY UP TO 300 MICROMETERS IN FRONT
OF THE STEAM VALVE. POSSIBLE DIRT BIGGER THAN 300 MICROMETERS MIGHT DAMAGE THE
STEAM VALVE AND CAN CAUSE ITS LEAKAGE.
For dimensions of steam connection information, see figures 1, 2 and technical specification table.
Use an inlet steam pressure hoses only, adapted to the steam valve with appropriate seal that is suitable
for the applied working pressure. Take care that by the installation and connection of the steam supply
the necessary measure are taken that accidental contact is prevented, this for all persons. Due to the high
temperature, direct injury will appear.
!
!
!