Technical data
549263_D_PUB_DATE_7_JUL_2014.DOC
INSTALLATION, MAINTENANCE AND USER' MANUAL
29
Rigid-mount machines 18 kg / 40 lb – medium spin
not standard
Phase
Voltage
[V]
Frequency
[Hz]
Total power
[kW]
Fuse
[A]
Motor output
[kW]
Heating
[kW]
Ingress
protection
IP
1 200-240
50/60 1.2
16
1.1
0
43
3
200-240
50/60
1.2
16
1.1
0
43
3
200-240
50/60
12.9
40 1.1 12 43
3
200-240
50/60
18.9
63 1.1 18 43
3
380-415 + N
50/60
1.2
10
1.1
0
43
3
380-415 + N
50/60
12.9
25
1.1
12
43
3
380-415 + N
50/60
18.9
32
1.1
18
43
3 380-415
50/60 1.2
10
1.1
0
43
3 440-480
50/60 1.2
10
1.1
0
43
3
380-415
50/60
12.9
25 1.1 12 43
3
440-480
50/60
12.9
25 1.1 12 43
3
380-415
50/60
18.9
32 1.1 18 43
3
440-480
50/60
18.9
32 1.1 18 43
Table 17 – Rigid-mount machines 18 kg / 40 lb – medium spin
Rigid-mount machines 24 kg / 55 lb – normal spin
not standard
Phase
Voltage
[V]
Frequency
[Hz]
Total power
[kW]
Fuse
[A]
Motor output
[kW]
Heating
[kW]
Ingress
protection
IP
1 200-240
50/60 1.2
16
1.1
0
43
3
200-240
50/60
1.2
16
1.1
0
43
3
200-240
50/60
19 63 1.1 18 43
3
380-415 + N
50/60
1.2
16
1.1
0
43
3
380-415 + N
50/60
19
32
1.1
18
43
3 380-415
50/60 1.2
10
1.1
0
43
3 440-480
50/60 1.2
10
1.1
0
43
3
380-415
50/60
19 32 1.1 18 43
3
440-480
50/60
19 32 1.1 18 43
Table 18 – Rigid-mount machines 24 kg / 55 lb – normal spin