Installation
549263_D_PUB_DATE_7_JUL_2014.DOC
INSTALLATION, MAINTENANCE AND USER' MANUAL
39
Recuperated water connection
WARNING!
DISCONNECT THE MACHINE POWER SUPPLY!
WHEN THE MAIN SWITCH IS TURNED OFF THE INLET TERMINALS OF THE MACHINE MAIN SWITCH
ARE STILL UNDER CURRENT!
Drill out the protective screens of the water inlet from
the recycle utilizing a drilling bit of 15mm / 0.59" diameter,
see Figure19. We do not recommend piercing the screens
open - it could lead to blockage of the water channel.
Inlet of water from the recycle into the machine – electrical
connection:
o
Connect the control of your recycle valve or recycle pump
onto the conductor of inlet valve (I5) or (I7) provided by the
manufacturer. By doing so, you disconnect the valve in question
from the standard function.
o
The manufacturer waives all responsibility for malfunction
of the washing machine in case that a different valve than
the specified “I5” or “I7” is used as the water recycle valve.
o
Fit a cable bushing into the opening (see Figure 19) and pull
the cable through the bushing.
o
Connect the coil for control of the recuperated water inlet
(the coil is not supplied with the machine), operating voltage
208-240V 50/60Hz).
o
Secure the cable in a suitable manner so that it is protected
against being pulled out of the machine or inlet valve.
Temperature range (°C/°F): -10/14 to 90/194.
Pressure: 8 bar / 116 PSI
Connection: outside diameter 19mm / 0.75".
The hose and the connector must be resistant to chemical
substances which are used for the washing process. It is also
possible to use a hose with enhanced performance
such as the rubber EPDM hose.
The recycling system must be fitted with a filter which must be
regularly and thoroughly cleaned (based on the water quality).
This cleaning prevents prolongation of filling up times and
malfunction of the water valves.
For programming method please refer to the Programming
manual.
!
INLET OF WATER FROM THE RECYCLE
(OUTSIDE DIAMETER 19mm / 0.75")
Figure 19
INLET OF CABLE FOR CONTROL OF THE WATER
VALVE OR PUMP FROM THE RECYCLE