AutoFocus User’s Guide
23
©1989-2018 Lauterbach GmbH
Loading and Storing the Settings of Sampling Points
For AutoFocus preprocessors, you can store the settings of the current session and re-load these settings
for the next session. Alternatively, you can copy and paste the stored settings into your start-up script. The
settings are then loaded automatically when you start TRACE32 with that start-up script.
Current session - To store the settings of the sampling points:
1.
In the
Trace.ShowFocus
window, click
Store
.
2.
Enter a file name, and then click
Save
.
Clicking the
Store
button calls
STOre
<filename>
AnalyzerFocus
and generates a PRACTICE
script similar to this:
New session - To re-load the stored sampling point settings:
1.
In a new
Trace.ShowFocus
window, click
Load
.
2.
Select the file containing the stored sampling point settings, and then click
Open
.
The sampling point settings are displayed in the
Trace.ShowFocus
window.
IF ANALYZER()
(
ANALYZER.TERMINATION ON
ANALYZER.THRESHOLD 1.19 0.99
; connect termination voltage
; during trace
; clock reference voltage
; = 1.19 V
; data reference voltage
; = 0.99 V
ANALYZER.SAMPLE TS -0.219
ANALYZER.SAMPLE PS0 -0.219
ANALYZER.SAMPLE PS1 +0.365
ANALYZER.SAMPLE PS2 +0.365
ANALYZER.SAMPLE TP0 -1.387
ANALYZER.SAMPLE TP1 -1.387
ANALYZER.SAMPLE TP2 -1.387
ANALYZER.SAMPLE TP3 -1.387
ANALYZER.SAMPLE TP4 -0.803
ANALYZER.SAMPLE TP5 -1.387
ANALYZER.SAMPLE TP6 -1.387
ANALYZER.SAMPLE TP7 -1.387
)
; Store trace channel sampling
; points
Trace.ShowFocus
as it
appears for a
re-programmable LA-7991