LAUNCH                      X-631/X-631+ Wheel Aligner                      Operation Instructions

 

4-22 

the sensor replacement operation has been 
performed ever. 
 

Data backup and restore 

The function is used in system data backup application, 
so as to prevent the WINDOWS system from abnormity 
caused by external factors (such as virus), and help 
you to avoid unnecessary loss. The backup function we 
provide is mainly used to backup the contents of three 
parts: user and business data information, system 
configuration file and probe calibration information. The 
interface is as shown in Fig.4.84. 

 

Fig.4.84 

 

Operating procedures: 

1. Backup: Click 

  button, find the position 

of the file you expect to save in pop-up dialogue box 
(The interface is as shown in Fig.4.82) or enter the 
path address directly in the blank of exported file path, 

and then click 

 button finally. 

 

Fig.4.85 

 

2. Restore: The similar operation can be performed 
when the backed-up data need to be imported into the 

system. Click 

  button, find the position of 

the file you expect to import in popped-up window or 
enter the path address directly in the blank of imported 

file path, then click 

  button, the system will 

automatically import this back-up file. 

Log Review 

Log is the important recorded information for the system 
running. We can check the system conditions by viewing 

the log, so we can say that the log is an important 
window for us to monitor and diagnose the system. 
During running and testing operation, the system will 
record some main operations or signals, in this way the 
information records in log file are built. The interface is 
as shown in Fig.4.86. 

 

Fig.4.86 

 

Operating procedures: 
[Log column]: To shown the abnormal conditions of the 
equipment usage in each year. 
 
[Save]: When there are records in the log file of system, 
the required records can be saved by 

clicking

button, and viewed by technical personnel, 

checking the running conditions of equipment. 
 
[Print]: The system has provided the printing function 
which is convenient to view. 
 

Note:  

Besides the client information needs backup operation 
regularly, we recommend that the log records need 
back-up operation regularly, too, so as to be convenient 
to repair and maintain the equipment. 

Print

In main interface, click the icon of [Print] to enter the 
interface of repot form print. It is mainly used to check 
or print the normal testing records of the client. The 
interface is as shown in Fig.4.87. 

 

Fig.4.87 

 

 

Select path 

Start to backup 

Start to restore 

Log column 

Save 

Print 

Print 

Client list 

Record list 

Содержание X-631 Plus

Страница 1: ......

Страница 2: ...request written permission to use Materials on this manual for purposes or for all other questions relating to this manual Copyright Information Copyright 2010 by Launch Tech Co Ltd All rights reserve...

Страница 3: ...for it may cause permanent damage to the system z The wires inside the cabinet and the probe rod sensors are connected compactly Any disconnection may cause damage to the sensor Damage due to unauthor...

Страница 4: ...ning triangle with the wording caution is on a safety reference personal injuries are not anticipated The applied symbol cannot replace the text of the safety reference The text must therefore always...

Страница 5: ...in the chargers provided in the delivery Protect from water sprays Do not open or short circuit electrical contacts Do not use if the housing has been damaged or if the electrical contacts have been...

Страница 6: ...1 Probe Rods 2 1 Wheel Clamps 2 3 Wheel Clamp Hanging Bracket 2 3 Turntables 2 3 Steering Wheel Holder 2 3 Brake Pedal Depressor 2 4 Calibrating Frame and its Converter Connector Optional 2 4 Basic O...

Страница 7: ...peed driving z When the tire s steering knuckle or shock absorber are replaced z When the vehicle is impacted z When the vehicle has covered the first 3000km or 10000km Main Vehicle Alignment Paramete...

Страница 8: ...steering will normally be designed with positive caster Thrust angle The thrust angle is defined according to the driven mode of vehicle z Rear wheel driven the thrust angle equals half of the toe in...

Страница 9: ...vehicle adjustment z Language operating prompt function z Emergency power supply and in time charging function z The probe rods provide LCD display function z Electronic level function z Black box se...

Страница 10: ...Rear camber f8 0 Thrust angle f5 0 Notes 1 The above measurement ranges can be confirmed only when the user follows the specified operation procedures Requirements on Surroundings Item Specification A...

Страница 11: ...s at the sideboard of cabinet The power lead is at the rear of the lower compartment inside the cabinet The power socket is at the spacer board and near to the sideboard The switch power supply is als...

Страница 12: ...tes the position of the bubble level as shown in Fig 2 7 Fig 2 7 The probe rod is level when the black float mark turns to OK as shown in Fig 2 8 Fig 2 8 Display for run out compensation To display th...

Страница 13: ...usting knob to adjust the span between wheel claws and then attach the clamp to the wheel rim Adjust the knob to make the wheel clamp fixed on wheel rim tightly Use the wheel clamp tie to bind the whe...

Страница 14: ...depressor is as shown in Fig 2 19 It is used to hold the brake pedal down Fig 2 19 Brake pedal depressor Calibrating Frame and its Converter Connector Optional They are mainly used to calibrate the p...

Страница 15: ...ck absorber tie rod ball and steering mechanism for any loose or wear Then check to see if the tire pressure tire treads of the left and right wheels are alike Wheel Alignment Checking Perform the whe...

Страница 16: ...l the probe rod by adjusting the bubble in the level gauge to the center position VII Plug the power cable of the Wheel Aligner into a standard power outlet of 3PIN Switch on the power supply of the c...

Страница 17: ...the probe rod s position dropped the level adjustment should take the electronic level as the standard Help To provide the description of operating method and note Operating procedures Select the corr...

Страница 18: ...tform for ride height measurement system in order to check if the ride height meets the design requirements of OEM Fig 4 8 Operating methods According to the prompts on the picture at the bottom of th...

Страница 19: ...y keep the four wheels on the ground Shake the vehicle body keep four wheels cling to the ground the run out compensation operation is finished The interface displays the values of run out compensatio...

Страница 20: ...fter finished 4 Push the vehicle back to the original position and then adjust all probe rods level Please click NEXT after finished Caster Swing Kingpin measurement is aimed at the front wheels which...

Страница 21: ...Fig 4 17 Caution 1 Before perform kingpin measurement please install brake pedal depressor and lock the hand brake first in order to ensure the vehicle wheels cannot move remove the steering wheel ho...

Страница 22: ...4 21 Fig 4 21 Note The system provides the dynamic measurement and display for these special values but the measurement result will not be saved in the database HELP for vehicle adjustment Click this...

Страница 23: ...ndividual toe in is not displayed HELP for vehicle adjustment Click this button the screen will pop up an interface of HELP for vehicle adjustment the different adjusting methods for various vehicle m...

Страница 24: ...reen Click NEXT button the screen will display the interface as shown in Fig 4 27 Fig 4 27 4 Put up the vehicle to position B2 according to the requirements of the manufacturer The screen display the...

Страница 25: ...ll Steering wheel is not centered Steering wheel swings and Others Save To save the alignment data of the vehicle under test Vehicle plate number and Client name must be entered and Fault cause must b...

Страница 26: ...splay left lateral offset right lateral offset axle offset front setback rear setback track width difference and wheelbase difference etc The interface is as shown in Fig 4 35 Fig 4 35 Select Vehicle...

Страница 27: ...te all the corresponding information including previous testing information of client Ensure that you do want to delete the information before performing Delete operation Print Print client informatio...

Страница 28: ...pplied in actual testing operation Demo version this version can in stand alone status simulate the testing process without external hardware equipments it hasn t testing ability only used to demonstr...

Страница 29: ...face is as shown in Fig 4 45 Fig 4 45 Select Language The system has provided many languages to select The interface is as shown in Fig 4 46 Fig 4 46 Operating procedures Select your desired language...

Страница 30: ...t this probe rod has been abnormal Status of probe rod In the Probe rod maintenance interface click the icon to enter the interface of the probe status Status of probe rod is used to display the commu...

Страница 31: ...XT after finished Fig 4 53 Remove FL probe rod install FR probe rod on FL wheel and then adjust the probe rod level Click NEXT after finished Fig 4 54 Remove FR probe rod install LR probe rod on FL wh...

Страница 32: ...match between the probe rod and the computer host Electronic Level Correction for Probe Rod In the interface of Probe Rod Maintenance please click the icon of Electronic Level Correction for Probe Rod...

Страница 33: ...rompts on the screen please click NEXT button to sample data The interface is as shown in Fig 4 64 Fig 4 64 According to the prompts on the screen switch on the power supplies of FL and RL probe rods...

Страница 34: ...n please click NEXT button to sample data The interface is as shown in Fig 4 70 4 70 According to the prompts on the screen install 4 probe rods and adjust them level switch on all power supplies of p...

Страница 35: ...click NEXT button to sample data The interface is as shown in Fig 4 76 Fig 4 76 According to the prompts on the screen turn the calibration frame shaft by 180 degrees install FL and FR probe rods and...

Страница 36: ...dicates that the calibration is successful this time If the calibrated value of any one of and inclinometer is equal to zero it indicates that the calibration is not successful this time and it is req...

Страница 37: ...y import this back up file Log Review Log is the important recorded information for the system running We can check the system conditions by viewing the log so we can say that the log is an important...

Страница 38: ...ment System Setting for the detailed settings The interface is as shown in Fig 4 91 Fig 4 91 New Functions of X 631 Wheel Aligner Added Functions for X 631 Wheel Aligner No PC Mode and the correspondi...

Страница 39: ...please press down key Previous and Next at the same time to enter the prompt interface for four probe rod working mode of No PC Mode Fig 4 95 Fig 4 96 After selecting working mode please press down k...

Страница 40: ...rking mode toe in is of total toe in indicated by TT when the system uses four probe rod working mode toe in is of individual toe in indicated by T 8 When X 631 wheel aligner uses No PC Mode the displ...

Страница 41: ...it and the monitor Please cleanout it with neutral detergent or dehydrated alcohol Avoid using oil or caustic product z Never disassemble the computer and move the inside cables and cards to avoid dam...

Страница 42: ...on or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY...

Страница 43: ...Q D UHVLGHQWLDO LQVWDOODWLRQ 7KLV HTXLSPHQW JHQHUDWHV XVHV DQG FDQ UDGLDWH UDGLR IUHTXHQF HQHUJ DQG LI QRW LQVWDOOHG DQG XVHG LQ DFFRUGDQFH ZLWK WKH LQVWUXFWLRQV PD FDXVH KDUPIXO LQWHUIHUHQFH WR UDGLR...

Отзывы: