L a u n c h T L T 2 6 0 A T T w o - p o s t l i f t u s e r ’ s m a n u a l
12
10.2.9 Lock release cable installation
Fig.15
10.2.10 Connect the hydraulic lines
Hydraulic lines is shown in Figure 16; please perform the connection according to the diagram and all the fittings shall
be tightened in order to prevent the oil leakage.
Note: When installing hoses, the carriage is at lowest position, to reduce the air in cylinder as much
as possible .Air bleeding is being conducted when debugging.
If the hose shall be installed through the column, ensure that the hose passage will not interfere with any
moving parts.
Rubber cushions must be added between the hydraulic station and the installation plate.