2.6 Water Connection  

 

It is necessary to install a water filter at the inlet of the chiller in order to 
avoid free particles in the water, which could block the evaporator plates 
or damage the pump. ultrafilter 

will not accept any warranty

 for the 

evaporator freezing if there is no water filter. An appropriate filter is the 
ultrafilter P-KG with a PPTF or similar with a filter element of 100 
microns or less. 
 
The water connection of the installation of the ultracool unit should be 
carried out according to the indications of the labels (stickers) present on 
the unit. 
 
The diameter of the inlet and outlet lines must be same size or larger 
than those corresponding to the water inlet and outlet of the ultracool 
unit. Always install thermal insulation for all pipes. 
 

In the installations in which the water level of the circuit exceeds 
the maximum level of the tank inside the ultracool unit, it will be 
necessary to install a non-return valve in the water outlet of the 
ultracool unit and a solenoid valve in the water inlet.  

The supply of this solenoid valve will be carried out by terminals 
designed for that purpose (see electrical diagrams).  
 

 

2.7 Electrical Connection  

 

The electrical design of the ultracool complies with UL 471 and          
EN-60204 norms. 

 

The electrical supply is 400V/3~/50Hz or 230V/3~/60Hz depending on 
the version.  
 
It must be checked that the supply voltage does not exceed a maximum 
variation of 10% referring to nominal.  
 
For the electrical supply of the ultracool unit, use an appropriate 
electrical line according to the data in the characteristics plate.  
  

A system of fuses or circuit breakers must be installed before the 
power inlet connection to the ultracool unit. The maximum size of 
these protections is defined in the electrical diagram.  

 
There are two prepared terminals to connect a remote on-off switch 
away from the unit. These terminals are at 24V.  
 
There are two prepared terminals in order to connect a solenoid valve to 
the water inlet to the ultracool unit, in such a way that when the ultracool 
unit starts, the solenoid valve opens up. These terminals are at 24VAC.  

 

UC-140 I

NDI

GO 

 50/

60Hz 29.

01.

03

 rev

. 0 

Содержание Ultracool Superplus series

Страница 1: ...OPERATION MANUAL ultracool mini 0140 Indigo Ref MI 080 Rev 1 Date 30 04 03 50 60 Hz...

Страница 2: ...The basic maintenance as indicated in point 5 1 should be carried out by properly trained personnel and if necessary under the supervision of a person qualified for this job ultrafilter personnel or p...

Страница 3: ...t up of the ultracool unit 7 3 3 Chiller strat up 8 4 Control Panel 4 1 Components of the control panel 9 4 2 Control thermostat 10 4 2 1 Operation 10 5 Maintenance 5 1 Basic maintenance 11 6 Troubles...

Страница 4: ...ded application in order to undertake additional safety measures if necessary 1 2 Safety regulations The operator has to observe the national working operating and safety regulations Also existing int...

Страница 5: ...compressor The ultracool unit must be transported by palet jack or forklift truck 2 3 Site The ultracool unit must be installed in an atmosphere where the range of temperatures is within the indicated...

Страница 6: ...nstallation the concentration of ethylene glycol should be checked Do not use automotive antifreeze Use lab grade ethylene glycol or refrifluid only Do not use an ethylene glycol concentration above t...

Страница 7: ...r outlet of the ultracool unit and a solenoid valve in the water inlet The supply of this solenoid valve will be carried out by terminals designed for that purpose see electrical diagrams 2 7 Electric...

Страница 8: ...of the ambient air Nominal 25 C 77 F Minimum 15 C 5 F 2 Maximum 50 C 122 F 1 For ambient temperatures below 5 C 40 F it is necessary to add ethylene glycol to the water of the circuit see point 2 4 3...

Страница 9: ...ial start up To do so start and stop the ultracool unit using the On Off switch it is easier to see the turn direction when the pump is stopping In the case of the pump rotating in the opposite direct...

Страница 10: ...when the compressor is working 7 Water level alarm indicator this is lit when the water level in the tank is too low It causes the ultracool unit to stop 8 Low flow temperature control indicator This...

Страница 11: ...probe In the 50Hz version the display shows the temperature in C and in the 60Hz version it shows it in F as depicted above Setting the temperature Follow these steps to introduce the required workin...

Страница 12: ...r filter if the pressure drop exceeds 0 5 bar 8 psi change the filter element Monthly With the Unit disconnected Main power switch Off clean the condenser with a blast of compressed air from the insid...

Страница 13: ...ation stopped Check the motor fan fuses If the problem persists contact authorised technical service Disconnect the chiller On Off and Main power switch both Off see point 4 Open the front panel of th...

Страница 14: ...following codes LO HI E0 Er2 EE The temperature has been below the setpoint for some minutes The temperature has been above the setpoint for some minutes Thermostat or temperature sensor is faulty If...

Страница 15: ...5 kW 1 1 1 0 max flow 4000 17 6 4000 17 6 min flow l h US gal min 400 1 8 400 1 8 max pres 6 3 91 6 3 91 Water pump min pres bar psi 3 3 48 3 3 48 Water tank volume litre US gal 100 26 100 26 Water co...

Страница 16: ...15 8 Log Book 8 Log Book 8 1 Log Book Date Remarks Signature UC 140 INDIGO 50 60Hz 29 01 03 rev 0...

Страница 17: ...below 50 S cm The product refrifluid supplied by ultrafilter includes in its composition an anticorrosive bactericide and antifreeze until 7 C 19 4 F It has the following characteristics Parameter Lim...

Страница 18: ...6003 E5326003 Sight glass 1 0107397000 0107397000 Refrigerant gas kg lb 14 31 R 134a R 134a Level control 1 E4202004 E4202004 Water by pass 1 E2301002 E2301002 Pump pressure gauge 1 E5544014 E5544022...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Отзывы: