Introduction 

 

1 Introduction  

 

1.1 General notes 

 

 

This water chiller complies fully with EC-machine directives and is UL and 
CSA listed. 

 

 

The Company does not accept responsibility if safety regulations are not met 
during handling, operation, maintenance and repair, even though these may 
not be strictly stated in this operation manual. 

 

 

We recommend the translation of this operation manual into the native 
language of foreign workers. 

 

 

The usability and life cycle of the water chiller as well as avoiding premature 
repairs depends on proper operation, maintenance, care and competent repair 
under consideration of this operation manual. 

 

 

We are constantly updating our products and are confident that they respond 
to the latest scientific and technological demands. However, as 
manufacturers, we do not always know the end use or the total range of our 
products’ applications. Therefore we cannot accept liability for our products in 
applications where additional safety measures may be necessary. We highly 
recommend that users inform us of the intended application in order to 
undertake additional safety measures, if necessary. 

 

1.2 Safety regulations 

 

The operator has to observe the national working, operating and safety 
regulations. Also, existing internal factory regulations must be met. 
Maintenance and repair work must only be carried out by specially trained 
personnel and, if necessary, under supervision of a person qualified for this 
work. 

 

 

Protective or safety devices must not be removed, modified or readjusted. 

 

 

During operation of the water chiller none of the protective or safety devices 
must be removed, modified or readjusted, temporarily or permanently. 

 

 

Only use correct tools for maintenance and repair work. 

 

 

Use original spare parts only. 

 

 

All maintenance and repair work must only be carried out to the machine 
once it has been stopped and disconnected from the power supply. Ensure 
that the water chiller cannot be switched on by mistake by unplugging it. 

 

 

Do not use flammable solvents for cleaning. 

 

 

Keep the surrounding area absolutely clean during maintenance and repair 
work. Keep free of dirt by covering the parts and free openings with clean 
cloth, paper or adhesive tape. 

 

 

Ensure that no tools, loose parts or similar are left inside the system. 

UC-140 I

NDI

GO 

 50/

60Hz 29.

01.

03

 rev

. 0 

Содержание Ultracool Superplus series

Страница 1: ...OPERATION MANUAL ultracool mini 0140 Indigo Ref MI 080 Rev 1 Date 30 04 03 50 60 Hz...

Страница 2: ...The basic maintenance as indicated in point 5 1 should be carried out by properly trained personnel and if necessary under the supervision of a person qualified for this job ultrafilter personnel or p...

Страница 3: ...t up of the ultracool unit 7 3 3 Chiller strat up 8 4 Control Panel 4 1 Components of the control panel 9 4 2 Control thermostat 10 4 2 1 Operation 10 5 Maintenance 5 1 Basic maintenance 11 6 Troubles...

Страница 4: ...ded application in order to undertake additional safety measures if necessary 1 2 Safety regulations The operator has to observe the national working operating and safety regulations Also existing int...

Страница 5: ...compressor The ultracool unit must be transported by palet jack or forklift truck 2 3 Site The ultracool unit must be installed in an atmosphere where the range of temperatures is within the indicated...

Страница 6: ...nstallation the concentration of ethylene glycol should be checked Do not use automotive antifreeze Use lab grade ethylene glycol or refrifluid only Do not use an ethylene glycol concentration above t...

Страница 7: ...r outlet of the ultracool unit and a solenoid valve in the water inlet The supply of this solenoid valve will be carried out by terminals designed for that purpose see electrical diagrams 2 7 Electric...

Страница 8: ...of the ambient air Nominal 25 C 77 F Minimum 15 C 5 F 2 Maximum 50 C 122 F 1 For ambient temperatures below 5 C 40 F it is necessary to add ethylene glycol to the water of the circuit see point 2 4 3...

Страница 9: ...ial start up To do so start and stop the ultracool unit using the On Off switch it is easier to see the turn direction when the pump is stopping In the case of the pump rotating in the opposite direct...

Страница 10: ...when the compressor is working 7 Water level alarm indicator this is lit when the water level in the tank is too low It causes the ultracool unit to stop 8 Low flow temperature control indicator This...

Страница 11: ...probe In the 50Hz version the display shows the temperature in C and in the 60Hz version it shows it in F as depicted above Setting the temperature Follow these steps to introduce the required workin...

Страница 12: ...r filter if the pressure drop exceeds 0 5 bar 8 psi change the filter element Monthly With the Unit disconnected Main power switch Off clean the condenser with a blast of compressed air from the insid...

Страница 13: ...ation stopped Check the motor fan fuses If the problem persists contact authorised technical service Disconnect the chiller On Off and Main power switch both Off see point 4 Open the front panel of th...

Страница 14: ...following codes LO HI E0 Er2 EE The temperature has been below the setpoint for some minutes The temperature has been above the setpoint for some minutes Thermostat or temperature sensor is faulty If...

Страница 15: ...5 kW 1 1 1 0 max flow 4000 17 6 4000 17 6 min flow l h US gal min 400 1 8 400 1 8 max pres 6 3 91 6 3 91 Water pump min pres bar psi 3 3 48 3 3 48 Water tank volume litre US gal 100 26 100 26 Water co...

Страница 16: ...15 8 Log Book 8 Log Book 8 1 Log Book Date Remarks Signature UC 140 INDIGO 50 60Hz 29 01 03 rev 0...

Страница 17: ...below 50 S cm The product refrifluid supplied by ultrafilter includes in its composition an anticorrosive bactericide and antifreeze until 7 C 19 4 F It has the following characteristics Parameter Lim...

Страница 18: ...6003 E5326003 Sight glass 1 0107397000 0107397000 Refrigerant gas kg lb 14 31 R 134a R 134a Level control 1 E4202004 E4202004 Water by pass 1 E2301002 E2301002 Pump pressure gauge 1 E5544014 E5544022...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Отзывы: