7.2 P-1 Operation parameters of entry phone
7 PROGRAMMING OF ENTRY PHONE
- these make the complete calling cycle. Any proportions may be set between the
signal generating time and the following break; furthermore time of an individual
tone (t1t) as well as tone frequencies F1 and F2 may be changed as well. Owing
to this a uniphone calling sound may be changed in a wide range.
t1t
2...20
[5] (U,H)
Time of individual tone generation PS.
Duration of an individual tone in ms (parameter value x 10 ms).
t1d
10...255 [100] (U,H)
Time of signal generation PD.
Duration of a signal consisting of tones repeated in cycles F1,F2,F3 expressed in
ms (parameter value x 10 ms).
tPA
20...255 [150] (U,H)
Pause time PA.
Break after signal generation in ms (parameter value x 10ms).
F1
50...255 [125] (U,H)
Signal frequency F1 in Hz (parameter value x 10 Hz).
F2
50...255 [175] (U,H)
Signal frequency F2 in Hz (parameter value x 10 Hz).
Electro-catch
trY
1...31
[5] (U,H)
Time of electro-catch operation.
Kind of numbering
nbl
0...9998 [0] (U)
Block number.
Value above 0 is set in electronic cassette servicing subordinate entrance switches on
mode with building numbering. This mode will operate properly if in electronic cas-
sette, which services the main entrance, mode with building numbering is switched.
Details in item ”Numbering”, see page 10.
Pnu
0...9998 [0] (U)
Range shift.
Parameter used in numbering mode with range shift. Details in item ”Numbering”,
see page 10.
LPi
0...100 [0] (U)
Amount of rooms on the floor.
Parameter used in hotel numbering mode in which room number is preceded by
a digit which defines the floor on which the room is located. Details in item ”Num-
bering”, see page 10.
30