COD. 83119L.01EN
09//2016
39
ALARM
CODE
DESCRIPTION
POSSIBLE CAUSE
SOLUTION
Er08
The speed of the
extractor cannot be
adjusted properly
It may appear sometimes because of
fluctuations in the electric main.
Reset the error and turn it on again.
Make sure it is connected to a suitable
supply.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
The voltage main is not good or is taken
from a non-sinusoidal AC generator
Fumes fan and/or any of its connections
are damaged
Er11
Update DATE and
TIME
It can appear the first time the stove is
connected to the network or after several
days of being unplugged.
Update time and day of the week. (See
chapter 6.2.3).
Er12
Error in the ignition
IF THE BURNER IS ALMOST EMPTY
There is little pellet in the hopper
. A “cave” in the hopper has been
formed, and the pellet does not get to
load auger.
The load auger is blocked and/or the
load motor does not turn.
Reset the error
Make sure that the pellet arrives to the
auger, put pellet in the hopper if
necessary, and fill up the auger (see
chapter 6.1.3).
If after several attempts of filling up
the auger, it does not fall pellet into the
burner, call the Technical Assistance
Service.
IF THE BURNER IS FULL OF PELLET
(NOT BURNED)
The burner is dirty.
Wet pellet or bad quality pellet
Ignition
resistance
and/or
the
connection cable are damaged.
Empty and clean the burner, reset the
alarm and try another start-up.
Check the conditions and quality of
pellet
If it does not start up after 2 or 3
attempts,
call
the
Technical
Assistance Service.
Er15
Electric supply cut
There has been an electric supply cut for
a long period while the stove was
working, or while the ignition.
Reset the error and start up again.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
Er39
Flow meter sensor
damaged
It may appear when the stove is turning
off if during the working the flow sensor
breaks down.
If the problem keeps on appearing,
when starting up the stove it will appear
the error “Er41”.
Er41
The minimum
airflow
has not been reached
during the “Check Up”
We may have a problem in the flue
duct.
The air inlet is blocked totally or
partially, or it has been canalized and it
has lot of load loss
Dirty burner
The stove takes air of an inlet
unplanned: the door is open or not
closed properly; the hopper and/or load
auger has no pellet, etc.
The interior fumes passages of the
stove are very dirty
The extractor has lost power
Problems with the flow sensor or its
connection
(appears
the
message
Check all the possibilities that appears
in the error “Er02”.
Check the stove and the installation
Check the stove cleanliness and flue
duct (see chapter 9)
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
Содержание AUDAX 10 KW
Страница 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...
Страница 2: ...COD 83119L 01EN 09 2016 2...
Страница 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...
Страница 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Страница 47: ...COD 83119L 01EN 09 2016 47...