COD. 83119L.01EN
09//2016
35
7.4 STATES OF WORKING
7.4.1
- STOVE STOPPED
State in which the stove is when it is connected to the main switch or after having switched it off.
In the display on top appears the time and in the display that is below the room temperature.
Stopped Stove
7.4.2
- IGNITION
When the stove is stopped or in standby and its working is required, the stove switches to ignition state.
This stage is subdivided in these 6 steps below: check “CHEC”, preheating “ON 1”, preload “ON 2”, fixed phase
“ON 3”, variable phase “ON 4”, and stabilisation “ON 5”.
7.4.3
- STOVE IS ON (NORMAL WORKING)
State of working of the stove when the electronic board detects that is already burning. During this stage, the user
can modify manually the power of working and the stove modulates the working power in function of the selected
temperature for the room thermostat; or the user can choose the automatic mode.
In the display on top it appears the time, and in the display that is below the working power and room temperature:
Pantalla durante el funcionamiento normal
7.4.4
- MODULATION (“MOD”)
State that appears during the normal working if it has been reached the room temperature of the selected
parameter or to adjust the fumes temperature, so the stove works at minimum power.
When the stove is in modulation, in the display on top it appears the Word “Mod” flickering.
Time
Room temperature
Time
Room temperature
Working power
Содержание AUDAX 10 KW
Страница 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...
Страница 2: ...COD 83119L 01EN 09 2016 2...
Страница 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...
Страница 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Страница 47: ...COD 83119L 01EN 09 2016 47...