background image

COD. 83119L.01EN

09//2016

9

2. IMPORTANT INSTRUCTIONS

Installation and use of the product should be in accordance with the manufacturer's instructions, obeying
European, national and local regulations where the product is installed.

This instruction manual has been prepared by the manufacturer and it is an essential part of the product. Should
the stove be sold or transferred, it should always be accompanied by the manual as it contains information that is
necessary for the buyer and all persons involved in the installation, maintenance and use of the product.

Carefully  read  and  understand  the  instructions  and  technical  information  contained  in  this  manual  before
proceeding  with  the  installation,  use  and  maintenance  of  the  product.  Familiarization  of  the  instructions  in  this
manual ensures the safety of people and a longer life performance of the product.

In case of problems or misunderstandings of the instructions, contact the installer.

The  manufacturer  disclaims  any  liability  for  damage  caused  by  failure  to  read  the  rules  and  instructions  for
installation,  use  and  maintenance  listed  in  the  book  of  instructions,  unauthorized  product  modification  or  use  of
non-original spares.

Installation,  electrical  connection,  maintenance  and  repairs  must  be  performed  only  by  a  qualified,  authorized
person and  with a  proper knowledge of the  product. Before the installation, check the flatness of the floor where
the  product  will  be  installed. The  installation must  be  carried  out  following  the  instructions  of  chapter

“5 –

INSTALLATION”

, many of which are manufacture advices and others are taken from the current local standards

at the time of writing the manual, so if there would be any modification of the standard, or the stove is installed in a
place that is subject to different rules, it will be necessary to adapt the installation of the stove to these standards.

Use of appropriate gloves is advised when handling coated parts to avoid leaving traces that are difficult to remove
in the first cleaning. The assembly of the stove should be carried by at least two people.

Connect the stove to the mains only after connecting the chimney.

Never use liquid fuels to start the stove.

Provide  sufficient  ventilation during the  installation.  In  case  of malfunction,  the  fuel  supply will  be  interrupted.
Restart the product only after having the cause of the problem solved. Stop using the product in case of failure or
malfunction. Do  not  lift  the  grating  which  lies inside the  fuel  hopper.  Any  accumulation  of unburned  fuel  in  the
burner resulting from misfire must be removed before ignition.
While  the  stove  is  working,  it is  recommended  not  to  touch  the  hottest parts  like  handle,  door,  chimney exhaust
and  glass.  Due  to  the  heat of  the  glass  door,  pay  attention to  keep anyone not  involved  in  the  installation away
from  the  stove. Inform  persons  in  the  vicinity  of  the  stove  of the  necessary precautions  while the  product and
possible products are working.

Do not place non heat-resistant objects on the stove or within the prescribed minimum safety radius of the stove
(check chapter

“5.3.1- MINIMUN SAFETY DISTANCES”

).

Do not open the door during operation, or start the stove if the glass is broken.

For terms, limits and exclusions refer to the warranty certificate supplied with the product. The manufacturer may
make  changes  deemed  appropriate  to  the  stove  documentation  without  notice,  to  pursue  a  policy  of  constant
development and constant renewal of the product.
This  document  is  property  of  the  manufacturer  and  cannot  be  transferred  in  whole  or  in  part  to  any  third  party
without the written consent of the company. All rights reserved.

DIRECTIVES AND STANDARDS

All our products are manufactured according to the following directives and standards:

2004/108/CE y 2014/30/UE
2006/95/CE
Regulation UE nº 305/2011

EN 60335-1; EN 60335-2-102;
EN 61000-3-2; EN 61000-3-3;
EN 50366; EN 55014-1; 55014-2
EN 14785

Содержание AUDAX 10 KW

Страница 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...

Страница 2: ...COD 83119L 01EN 09 2016 2...

Страница 3: ...this manual carefully because it will furnish important instructions regarding the safe installation use and maintenance o Installation of Air LASIAN stoves must be carried out by qualified personnel...

Страница 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...

Страница 5: ...n its different models AUDAX 6 KW AUDAX 8 KW AUDAX 10 KW AUDAX 12 KW WE HEREBY DECLARE under our sole responsibility that the above mentioned products are manufactured in accordance with the following...

Страница 6: ...OF THE DUCT 19 5 4 3 USE OF A TRADITIONAL TYPE CHIMNEY 20 5 4 4 USE OF EXTERNAL CHIMNEY 21 5 4 5 FLUE DUCT ENDING 21 5 5 VENTILATION AND FRESH AIR INTAKE 22 5 6 ELECTRICAL CONNECTION 23 6 INSTRUCTION...

Страница 7: ...WITCH OFF OFF 36 8 PROBLEMS MESSAGES AND ALARMS 36 8 1 PROBLEMS 37 8 2 MESSAGES 37 8 3 ALARMS 38 9 CLEANING AND MAINTENANCE 40 9 1 MAINTENANCE TABLE 41 9 2 DISPOSAL OF ASHES 42 9 3 BRAZIER CLEANING BU...

Страница 8: ...requires particular attention In some cases it can be used capital letters or increase the font size to draw attention to some paragraphs Text in italics is used to draw your attention to other parag...

Страница 9: ...o these standards Use of appropriate gloves is advised when handling coated parts to avoid leaving traces that are difficult to remove in the first cleaning The assembly of the stove should be carried...

Страница 10: ...ve respecting the distances so that it is always visible MODEL AUDAX 6 kW AUDAX 8 kW AUDAX 10 kW AUDAX 12 KW Nominal thermal output min max kW 3 5 6 4 3 9 8 2 3 7 10 4 3 8 12 Efficiency at nominal red...

Страница 11: ...ed sawdust extracted from the remains of the production and processing of dried natural wood the compactness of the product is guaranteed over time by a natural substance contained in the wood the lig...

Страница 12: ...eters and lengths are valid for use in boilers 4 2 WHAT DO YOU HAVE TO KNOW ABOUT THE PELLET A certified pellet under any of the two previous standards DIN plus EN plus A1 would be the best guarantee...

Страница 13: ...NDING ON THE PELLET THAT HAS BEEN USED As we have already explained in the previous section is clear that when the fuel that we use in the stove is changed this behavior may be different and although...

Страница 14: ...high temperatures you have to follow certain rules and safety recommendations to prevent possible fires and dangerous situations so to make the installation check paragraph 5 3 DOMESTIC FIRE PREVENTIO...

Страница 15: ...tove and play an important role to prevent possible fires 5 4 1 GENERAL NOTES It is recommended to keep out of the heat source area at least at 1 5 meters all flammable or combustible items such as wo...

Страница 16: ...separate the stove from the floor We will use for this a fire resistant material such us a Steel sheet marble or tiles Whatever type of protection is chosen it must be able to withstand without defor...

Страница 17: ...of paragraph 5 4 2 CHOICE AND CALCULATION OF THE DUCT The inner section should be uniform preferably circular square or rectangular sections must have rounded edges with a radius of at least 20 mm re...

Страница 18: ...COD 83119L 01EN 09 2016 18 Fig 5 3 Fig 5 4 Fig 5 5 Yes Yes Direction of cleaning Direction of cleaning Direction of cleaning Sealing plug...

Страница 19: ...hs are counted from the T output of the stove and it is from there where it should be increased the diameter of the duct if it is necessary see fig 5 6 LIMITATIONS WITH 80 mm PIPE WITH DOUBLE WALLED 1...

Страница 20: ...gly recommended that you have it checked by a professional chimneysweep to ensure that it is completely airtight The reason for this is that the smoke because it is slightly pressurized can infiltrate...

Страница 21: ...not less than twice of the flue pipe section o It must prevent the penetration of rain snow or foreign matter o The cowl must be installed to ensure the adequate dispersion and dilution of the combust...

Страница 22: ...jacent room to the place of the installation provided this air flows freely through permanent apertures that cannot be closed and communicate with the outside The adjacent room must not be used as a g...

Страница 23: ...er cord first behind the stove and then into an electrical outlet on the wall The main switch located on the back wall will be activated only when the stove is lit otherwise it is advisable to remove...

Страница 24: ...king Display D4 Room temperature and parameter values The push buttons have different functions depending on the screen we are in and depending on whether the keystroke is short Clic or long long keys...

Страница 25: ...n we see in the display that is below the abbreviation of the name of parameter and in the display on top their value The parameters to visualise in order of appearance are tF Fumes temperature C tA R...

Страница 26: ...ing We will interrupt the load when the pellet falls off steadily in the burner for which you just have to push any button Due to security reasons the load will be interrupted automatically after 300...

Страница 27: ...ment will not appear or if it appears must remain at 0 in order not to interfere with the electronic board adjustment 6 1 7 COMBUSTION FAN CALIBRATION DEACTIVATED FROM FACTORY The pellet combustion an...

Страница 28: ...peed depending on the working power of the stove at your disposal 6 2 2 SCHEDULE PROGRAMMING CRON This function allows the schedule programming of ignition shutdown the stove It is formed by two secti...

Страница 29: ...ay Friday Saturday Sunday MF SS For the schedule of ON the segment turns on below in the display D2 1I Mo For the schedule of OFF the segment turns on in the upper side of the display D2 1I Mo For eve...

Страница 30: ...the schedule of ignition push the button P3 to enter and the modification and the selected value hours and minutes will start to flicker Push the button P3 to switch from hours to minutes and vice ver...

Страница 31: ...ext day of the week Tuesday in this case the schedule of ON at 00 00 Crono programming Monday ON 22 00 1I Mo 23 59 1I Mo OFF Crono programming Tuesday ON 00 00 1I Tu 07 00 1I Tu OFF 6 2 3 TIME AND DAT...

Страница 32: ...is to enter to the SAT parameters that are reserved to the Technical Assistance Service The access is protected by a password 7 USE AND WORKING OF THE STOVE 7 1 ADVICE AND WARNING Do not use the stove...

Страница 33: ...at case the manufacturer will be exempt from criminal or civil liability The stove experiences changes of expansion and contraction during the phases of heating and cooling so it is completely normal...

Страница 34: ...on the stove push the button for some seconds until you hear a whistle and it will appear on the lower right side the working power that has been selected see the section 6 1 2 Screen during the star...

Страница 35: ...f the stove when the electronic board detects that is already burning During this stage the user can modify manually the power of working and the stove modulates the working power in function of the s...

Страница 36: ...can start by different reasons If we force a switch off with the push button ON OFF When the stove enters in standby mode When it appears any message of error When the stove is in ignition recovery Du...

Страница 37: ...e voltage in the plug see if the rear switch is on maybe the rear fuse is burnt out In days of strong wind or adverse weather conditions it is possible that the stove combustion is not good due to the...

Страница 38: ...fumes temperature There is little pellet in the hopper A cave in the hopper has been produced and the pellet do not arrive to the load auger The load auger has been blocked or and the load motor does...

Страница 39: ...gnition resistance and or the connection cable are damaged Empty and clean the burner reset the alarm and try another start up Check the conditions and quality of pellet If it does not start up after...

Страница 40: ...to turn off the stove for some seconds pushing the back switch If after have followed every single step of how to reset the alarms and you do not get to reset the stove or if every time you try to st...

Страница 41: ...CLEANING USER check paragraph 9 8 X T CONNECTION CLEANING USER check paragraph 9 7 X COMBUSTION CHAMBER CLEANING PROFFESIONAL OR AUTHORIZED TAS check paragraph 9 5 X FUEL HOPPER CLEANING USER check pa...

Страница 42: ...event the overflow of ashes To take out the ash pan introduce the two fingers into the holes see Fig 9 1 pull it upwards and then outwards see Fig 9 2 Ashes must be placed in a metal container with a...

Страница 43: ...cold and it would be desirable to do before every start or at least once a day To perform this cleaning we have on the front of the stove one or two knobs depending on the stove model Moving them bac...

Страница 44: ...operation depends on the type of fuel used and the frequency of use To perform this cleaning it is advisable to contact a Technical Assistance Center 9 7 UNLOAD INSTALLATION CLEANING CHIMNEY It is rec...

Страница 45: ...all particles accumulated at the bottom Never remove the protection grille which is inside the hopper 9 10 ANNUAL INSPECTION We call Annual Inspection to an extraordinary maintenance in which a comple...

Страница 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...

Страница 47: ...COD 83119L 01EN 09 2016 47...

Страница 48: ...unit and for manufacturing defects NOTE The manufacturer reserves the right to make product changes without notice always maintaining the technical and essential service characteristics to fulfill th...

Отзывы: