COD. 83119L.01EN
09//2016
40
“Sond”)
ALARM
CODE
DESCRIPTION
POSSIBLE CAUSE
SOLUTION
Er42
Excessive airflow
during the “Check Up”
It may appear if we had an excessive
draught in the chimney, or if we are
forcing the air inlet for the pellet.
Check and correct the installation.
In case that this alarm appears often,
or in case you do not get to reset it,
inform
the
Technical
Assistance
Service.
The pressure switch is damaged, and in
this case, it may appear with the
message “Sond”.
Inform
the
Technical
Assistance
Service
With the help of this alarms table, the user should be able to identify the cause of the
alarm.
Once the cause has been detected and corrected, to turn on the stove again it is
necessary to reset that alarm.
RESET OF THE ALARMS:
When an alarm is produced, the stove starts turning off.
The alarm cannot be reset until the stove is completely off.
Once the stove is off you have to wait until in the display on top appears “Alt” and push
for some seconds the button
to reset the alarm that is active.
Once the alarm has been reset, it is advisable to turn off the stove for some seconds
pushing the back switch.
If after have followed every single step of how to reset the alarms and you do not get to reset
the stove, or if every time you try to start again the stove the alarm keeps appearing, inform the
Technical Service.
9. CLEANING AND MAINTENANCE
For a proper functioning of the stove it is essential to carry out certain maintenance tasks, which often depend
primarily on the operating hours and the fuel quality. Some of them must be carried out daily, whereas others just
make them once a season.
The user is responsible for carrying out the cleaning and maintenance tasks, some of these tasks have to be
carried out directly by the user and others contacting a qualified staff or authorized TAS.
When the message “CLr” is displayed on the screen (Ordinary Maintenance), the user must carry out or make sure
that the maintenance tasks marked with an asterisk
(*)
have been carried out recently, check paragraph
“9.1-
MAINTENANCE TABLE
”.
When the message “Serv” is displayed on the screen (Extraordinary Maintenance), the user should contact a
qualified staff or authorized TAS in order to carry out, if it has not been performed recently, the maintenance tasks
marked with
(**)
, check paragraph “
9.1- MAINTENANCE TABLE
”.
Содержание AUDAX 10 KW
Страница 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...
Страница 2: ...COD 83119L 01EN 09 2016 2...
Страница 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...
Страница 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...
Страница 47: ...COD 83119L 01EN 09 2016 47...